ICE MAKER
Before the ice maker can operate, make sure that:
The refrigerator is connected to 120 V AC .
The water valve supplying the refrigerator is turned on.
The ice level bail arm is in its fully down position.
How it works
When the ice maker thermostat senses the preset temperature
for the ejection of the ice cubes, the fi ngers will start to rotate,
dumping any ice cubes and fi lling the mold with water. When
the storage container is full, the bail arm will come in contact
with the ice cubes. The bail arm cannot return to the full down
position and the ice production is stopped until the bin is emp-
tied, or ice cubes are removed.
To prevent water from splashing out of the mold assembly
when your recreational vehicle is moving, raise the bail arm to
the full “UP/OFF” position about 1-1/2 hours before departing.
This will allow the water in the mold to freeze.
Water supply
The water supply system must have a minimum pressure of
15 pounds per square inch gauge (psig). A 1/4” diameter water
line to the water valve should be used at the rear of the refrig-
erator. The water line must have a manual shutoff valve placed
where it is easily accessible.
The maximum water level is represented by a thin line. It is
essential that the water level does not exceed this line!
If necessary change the water fl ow by adjusting the water sup-
ply, see the step-by-step instruction in
ADJUSTING THE SIZE
OF CUBES.
OPERATING INSTRUCTIONS
SETTINGS
Set real time clock
If the real time clock has to be set the LED panel will show
ashing horizontal bars ” -- -- “.
To enter TIME MODE keep SET key pressed until
gures fl ash on the LED panel. Hours are to the left
and minutes to the right.
Press SET key to adjust to local time. PM or not
should also be set here.
Store each setting by pressing AUTO/STORE key or
use the automatic store function (wait 5 sec.).
Set thermostat range
Press SET key to desired thermostat range, 1 to 5
where 5 represents the coldest compartment tem-
perature.
To store, press the STORE key or use the automatic
store function (wait 5 sec.).
Select energy mode of operation
Press AUTO/STORE key to select Auto mode opera-
tion or locked up to LP-gas mode operation only.
Current mode of operation and energy source, AC or GAS is
indicated by a dot on the LED panel.
Manual defrost
The refrigerator can be set to defrost manual at any time. Usu-
ally a defrost cycle takes about 1 hour but is depending on the
amount of frost and could therefore vary from time to time.
Before entering manual defrost mode, switch off the
refrigerator with the ON/OFF key.
To enter manual defrost, press and hold AUTO/
STORE key. Then, press the ON/OFF key. “dE Fr” is
displayed on the LED panel.
1.
2.
3.
1.
2.
1.
2.
Ice level
bail arm
Dow
n
positio
n
PM INDICATION HOURS MINUTES
START-UP
Before turning on the refrigerator, please verify that all the
manual gas valves (including the manual shut off valve) are in
the ON position. Then press the ON/OFF key.
Maximum
water level