User manual

– 7 –
To remove the refrigerator, follow these steps:
Cap the gas supply line.
Loosen the screws anchoring the refrigerator to the
enclosure.
Slide the refrigerator out of the compartment.
When replacing the refrigerator make sure that the sealing
strips are properly positioned. Check all connections for gas
leaks. Replacement is the reverse of removal.
1.
2.
3.
ELECTRICAL CONNECTION
120 V AC connection
The refrigerator is equipped with a three-prong (grounding)
plug for your protection against shock hazards and should be
plugged directly into a properly grounded three prong recep-
tacle. DO NOT cut or remove the grounding prong from this
plug!
The free length of the cord is 2 feet and it is recommended that
the receptacle is located to the right side of the refrigerator
(viewed from the rear).
The receptacle should be 3” (from the
bottom of the plastic receptacle) above
the refrigerator mounting floor. This al-
lows easy access through the vent door.
The cord should be routed to avoid direct
contact with components that could
damage the cord insulation.
120 Volt AC
receptacle
3’
GAS/ELECTRICAL CONNECTION
12 V DC connection
The refrigerator requires a continuous 12 V DC supply to main-
tain the automatic energy selector system and the auto defrost
control system to function.
The connection is made to the positive (+) and negative (-)
terminals of the terminal block on the back of the refrigerator.
Correct polarity must be observed when connecting to the DC
supply. Do not use the chassis or vehicle frame as one of the
conductors. Connect two wires at the refrigerator and route to
the DC supply.
Maximum fuse size for the DC supply is 10 A.
It is important that the wires to the 12 V DC terminal is
of proper wire size. The following table displays the recom-
mended size and length of the conductor wires.

Length Min. size
< 33 ft
< 10 m
12 AWG
33 - 66 ft
10 - 20 m
10 AWG
> 66 ft
> 20 m
8 AWG
Example: If the distance between the refrigerator and the
12V DC supply is 20 ft., the total wire length is 40 ft. and
a wire size of 10 AWG should be used.
Before removing the refrigerator:
Verify that the AC voltage and DC voltage leads are
disconnected.
Shut off the gas supply.
Disconnect the gas supply line at the rear of the refrigerator.
Always use a back up wrench when loosening and tighten-
ing connections.
REFRIGERATOR REMOVAL