User manual
– 6 –
GAS CONNECTION (NDA1402)
Hook up to the gas supply line is accomplished at the manual
gas valve, which is furnished with a 3/8” SAE (UNF 5/8” -18)
male fl are connection. All completed connections should be
checked for leaks with soapy water.
Do not use a fl ame to check for gas leaks!
The gas supply system must incorporate a pressure regulator
to maintain a supply pressure of not more than 11 inches water
column. When testing the gas supply system at test pressures:
> 1/2 psi
- the refrigerator and its individual shutoff valve
must be disconnected from the gas supply piping system.
≤
1/2 psi
- the appliance must be isolated from the gas
supply piping system by closing its individual manual shut-
off valve.
For detailed instructions on the installation and connection to
the gas supply, contact your dealer or distributor.
•
•
INSTALLING THE DRAIN WATER HOSE
To install the drain water hose, follow these steps:
Drill a hole through fl ooring. It is essential that it is
drilled in the cut out opening of the base plate at the
rear of the refrigerator.
Make sure that the hose does not kink when run
through the fl oor.
Seal around the hose that goes through the drilled
hole. If a longer hose than supplied is required, the
installer needs to supply one in order for the water to
drain outside of the vehicle.
1.
2.
3.
Testing LP gas safety shut off
The gas safety shut off must be tested after the refrigerator is
connected to LP gas supply. To test the gas safety shut off, fol-
low these steps:
Turn on the refrigerator and switch to GAS mode.
Check that the GAS indicator dot is illuminated and
the gas fl ame is lit.
Close the manual gas shut off valve at the back of
the refrigerator.
Wait for approx. 6-7 minutes. The message
“ch LP” is displayed (fl ashing).
Remove the protection cover.
Open the manual gas shut off valve. (Do not change
any button positions on the control panel.)
Apply a non corrosive commercial bubble solution
to the burner jet orifi ce. No bubbles should appear at
the opening of the burner jet orifi ce. The presence of
bubbles indicates a defective gas safety shut off, and
service is required.
If no bubbles were present at the burner jet orifi ce,
rinse it with fresh water. Be careful not to damage
the burner jet orifi ce.
Put back the cover.
Switch the refrigerator OFF and back ON again.
Normal operation of the burner should return.
Allow the burner to operate for a minimum of 5
minutes
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Hole for drain
water
hose
INSTALLATION INSTRUCTIONS
GAS/ELECTRICAL CONNECTION
WARNING
!