User manual

- 9 -
The gas supply system must incorporate a pressure regulator
to maintain a supply pressure of not more than 11 inches water
column. When testing the gas supply system at test pressures:
> 1/2 psi
must be disconnected from the gas supply piping system.
≤ 1/2 psi - the appliance must be isolated from the gas
-

If detailed instructions on the installation and connection to
the gas supply are required, please contact your dealer or
distributor.
Testing LP gas safety shut off
The gas safety shut off must be tested after the refrigerator is

Rm2354, Rm2454, Rm2554, Dm2662, Dm2663,
Dm2862, Dm3862, nDm1062 & nDR1292
To test the gas safety shut off, follow these steps:
Start the refrigerator. Switch to GAS mode.

indicator lamp is on.

refrigerator.

lamp should be lit and the GAS mode indicator lamp
should be off.


any button positions on the control panel.






rinse it with fresh water. Be careful not to damage the


-
mal operation of the burner should return.

minutes.
Rm2351, Rm2451, Rm2551, Dm2652 & Dm2852
To test the gas safety shut off, follow these steps:
Start the refrigerator without connecting to
120V AC.



1.
2.
3.
4.
5.
6.

8.
9.
10.
11.
1.
2.
3.
DRain wateR hose


Seal around the hose that goes through the drilled hole. If a
longer hose than supplied is required to get the water to drain

length of hose.
connections
Gas connection


-

installation instRuctions
Drill the hole in the cut out
opening of the base plate
Hole for drain
water hose
NDR1292
EXPLOSION HAZARD. Never use an open
ame to check for gas leaks. Failure to heed this
warning could cause an explosion resulting in
death or severe personal injury.
WARNING
!
Hole for drain water hose
RM2451, RM2454, RM2551, RM2554, DM2652, DM2662,
DM2663, DM2852, DM2862, DM3862 & NDM1062
Hole for drain water hose
RM2351 & RM2354