User manual
5
INSTALLATION
GAS CONNECTION
Hook up to the gas supply line is accomplished at the manual
gas shutoff valve, which is furnished with a 3/8” SAE (UNF
5/8” -18) male flare connection. A backup wrench must be
used when tightening gas supply fitting. All completed con-
nections should be checked for leaks with a noncorrosive leak
detector.
WARNING! DO NOT use a flame to check
for gas leaks.
The gas supply system must incorporate a pressure regulator
to maintain a supply pressure of not more than 11 inches water
column.
When testing the gas supply system at test pressures in excess
of 1/2 psi, the refrigerator and its individual shutoff valve must
be disconnected from the gas supply piping system. When test-
ing the gas supply system at pressures less than or equal to 1/2
psi, the appliance must be isolated from the gas supply piping
system by closing its individual manual shutoff valve.
In case detailed instructions on the installation and connection
to the gas supply are required, contact your dealer or distribu-
tor.
TESTING LP GAS SAFETY SHUTOFF
The gas safety shutoff must be tested after the refrigerator is
connected to the LP gas supply. To test the gas safety shutoff,
proceed as follows:
Start the refrigerator according to the instructions for
Gas Operation; section “Operation Instructions”.
Check that the gas flame is lit. This can be observed
through the reflector (E).
Close the gas valve by turning the knob (A) back to
“OFF” position.
Wait for one minute.
Remove burner cover plate, one screw at the burner.
Open the gas valve by turning the knob (A) to posi-
tion “GAS” without pushing the buttons (C) and
(D). Apply a non-corrosive commercial bubble solu-
tion to the burner jet.
No bubbles should appear at the opening of the
burner jet. The presence of bubbles indicates a defec-
tive gas safety shutoff, and service is required.
If no bubbles were present at the burner jet, the gas
safety valve is working properly. Rinse jet thorughly
with fresh water before proceeding. Be careful not
to damage the burner jet. Replace the burner cover
plate and turn the knob (A) back to “OFF”. Start
the refrigerator by following the instructions for Gas
Operation, section “Operation Instructions”. Normal
operation of the burner should return. Allow the
burner to operate for a minimum of 5 minutes.
1.
2.
3.
4.
5.
6.
7.
ELECTRICAL CONNECTION
120 Volt AC Connection
The refrigerator is equipped with a three-prong (grounding)
plug for your protection against shock hazards and should be
plugged directly into a properly grounded threeprong recep-
tacle. DO NOT cut or remove the grounding prong from this
plug. The cord should be routed to avoid direct contact with
the burner cover, flue cover or any other components that could
damage the cord insulation.