miniBar INSTRUCTIONS for USE INSTALLATION INSTRUCTIONS compressor RECORD THIS INFORMATION FOR FUTURE REFERENCE BEFORE INSTALLING THE UNIT: Model No. Serial No. Product No. Date Purchased Place of Purchase Sales Office Intercon Marketing 1540 Northgate Blvd. Sarasotu, Fl 34234 Phone: 941-355-4488 SERVICE OFFICE The Dometic Corp. 509 So. Poplar St.
TABLE of CONTENTS 1.0 INTRODUCTION 3 2.0 FOR YOUR SAFETY 3 2.1 Warnings and Safety Advice 2.2 Coolant 3 3 3.0 WARRANTY AND CUSTOMER SERVICE 3 4.0 INSTALLATION 4 4.1 4.2 4.3 4.4 4.5 4.6 The Purpose of this Manual Tools/Materials Required Unpacking Cleaning Technical Data Connecting the Device to the Electricity Supply 4.7 Securing 4.8 Installation 4.9 Changing the Sliding Hinge 4.10 Changing the Doorhang 4 4 4 4 5 7 INSTRUCTION for USE 9 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.
1.0 INTRODUCTION You have made an excellent choice by choosing the Dometic miniBar. We are convinced that you will be satisfied with your new appliance in every way. This compressor miniBar fulfils high quality standards and guarantees an efficient use of resources and energy during its entire working life, i.e. during manufacturing, use and disposal. Please study the installation and operating instructions carefully before attempting to operate the miniBar. 2.0 FOR YOUR SAFETY 2.
.0 4.1 INSTALLATION The Purpose of this Manual The manual shows you how to: install the miniBar correctly. operate the miniBar correctly. guarantee the miniBar´s correct maintenance and functioning. deal with faults by yourself. 4.2 Tools / Materials Required You will need the following tools for initial operation: mild detergent 4.3 Unpacking Check during unpacking that the device is defect-free. Report transport damage to the transport company within 48 hours.
4.5 Technical Data Model RHC 460 RHC 860AC / MBC 600A Casing metal metal Gross Contents ( litres) 53 53 cooled / uncooled 53 / - 53 / - 563 x 486 x 476 612 x 486 x 476 Electrical Rating (W) 50 50 Power supply 115V-120V / 60Hz 115V-120V / 60Hz Residual current 9.5 A max Dimensions (mm) (H x W xD) 9.
4.8 Installation min. 200cm² min. 20mm min. 200cm² IMPORTANT: Please follow the installation details below carefully. Guarantee is valid for products installed as described only. 1. The miniBar must be level both directions. 2. There should be 20mm clearance to the wall. 3. Ventilation must be provided as shown in alternatives A, B, C or D. 4. The ventilation duct must at least measure 105mm x the width of the refrigerator. 5. Only the entire cooling unit must project into the duct as shown.
4.9 Changing the Sliding Hinge 1. 2. 1. 2. 3. 4. Distance to cupboard door (A) 1. mm A 2. mm 1. When closed, the cupboard door (A) must not lie against the rest of the surrounding cupboard area (distance 1-2mm). 2. There must be a distance of 6-8mm between the cupboard door and the miniBar.
4.10 Changing the Doorhang 1. L R 2. 3. 2. 1. 4. 5. 7. 6. R L 1. 2. 8. 12. 9. 10. 13. 8 11.
5.0 5.1 INSTRUCTION for USE Initial Operation The device must be plugged into a properly earthed socket. The miniBar achieves its operating temperature after approx. one hour. RHC 860AC: Please refer to the installation advices of the AMS system manual! 5.2 Temperature Control The temperature in the cooling compartment can be regulated with a thermostat. The thermostat control button is situated in the compartment’s rear area. 5.
5.4 Check List Failure : No cooling (the aggregate at the back of the device is cold). Possible Cause Self Help a.) The thermostat is set to “0”. a.) Set temperature control to middle position. b.) The device plug is not plugged in. b.) Plug in device plug. c.) No voltage in socket. c.) Check building fuse.. Authorised Service Failure : No cooling (the aggregate is warm). Possible Cause Self Help a.) The device was only switched on a short while ago. a.
5.5 Environmental Advice miniBars manufactured by Dometic GmbH are free from CFCs / HCFCs and fluorinated hydrocarbons. The cooling unit uses R134a as the coolant Cyclopentane, which does not damage the ozone layer, is used as propellant for the insulation made from PU-foam. 5.6 Disposal In order to ensure the re-use of recyclable packaging materials, these must be disposed of using local collection systems.
Tel.: +49-(0) 271 / 692 0 Fax: +49-(0) 271 / 692 300 www.dometic.de/minibar www.dometic.