BEDIENUNGSANLEITUNG EINBAUANLEITUNG ABSORBER - KÜHLSCHRANK für CARAVAN und REISEMOBIL RM 4361DM RM 4361NDM Deutsch Seite 2 English page 8 Typ C40 / 110 821 2684-50 MANUAL ABSORPTION REFRIGERATOR for CARAVAN and MOTORHOME T.B.
INTRODUCTION CONTENTS OPERATING INSTRUCTIONS CONTROLS STARTING THE REFRIGERATOR WINTER OPERATION REGULATING THE TEMPERATURE TRAVEL CATCH FOOD STORAGE ICE-MAKING DEFROSTING CLEANING THE REFRIGERATOR TURNING OFF THE REFRIGERATOR IF THE `FRIDGE FAILS TO WORK MAINTENANCE SOME USEFUL HINTS GUARANTEE AND SERVICE LP GAS CONNECTION TECHNICAL DATA ELECTRICAL CONNECTION DECLARATION We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-m
OPERATING INSTRUCTIONS 7. When the flame lights, the sparking stops automa tically and the switch stops flashing. 8. Keep the (D) button pressed for a further 10 to 15 seconds to active the flame failure device, then release it. CONTROLS 230 V Operation 1. Turn off gas or 12 V operation when applicable. 2. Turn the knob (C) of the thermostat to its highest (coldest) position. 3. Set switch (B) to position I. The switch will light up green when the power supply is connected. FIG.
TRAVEL CATCH plastic surfaces of the refrigerator. Neither should any sharp objects be used to scrape off the ice. The defrost water runs from a collector channel to a receptacle at the rear of the refrigerator where it evaporates. Defrost water in the freezer compartment should be mopped up with a cloth. When the ice has melted, wipe the refrigerator dry and restart it. Place the food items back inside but wait until the refrigerator is cold before making ice cubes.
6. If the refrigerator fails to work on 230/ 240 V, check: That the 230 V supply is connected to the refrigerator. That the fuse is intact. If the refrigerator is not cold enough it may be because: 1. The ventilation is inadequate owing to reduced area of the ventilation passages (partial blockage of grilles from wire mesh etc). 2. The evaporator is frosted up. 3. The temperature control setting is incorrect. 4. The gas pressure is incorrect - check the pressure regulator at the gas container. 5.
gned for the type and diameter of the connection pipe used, and screwed joints should be sealed with a joining compound approved for use with bottled gas. The gas supply pipe should be connected to the gas inlet pipe on the right hand side of the gas control valve by means of a suitable threaded compression coupling. In making the connection to the refrigerator, a union gas cock of an approved type bottled-gas must be incorporated in the supply line in a position which is readily accessible to the user.
DECLARATION 13
Dometic GmbH In der Steinwiese 16 D-57074 Siegen www.dometic.de/caravan www.dometic.