MANUAL CARAVAN RA/RM-2D 0402 RM 4601 822 70 89-06 Piezo igniter version page 3 Reigniter version page 11
OPERATING AND INSTALLATION INSTRUCTIONS FOR DOMETIC REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: OPERATING INSTRUCTIONS ............................ 4 CONTROLS .................................................... 4 It is important to read through these instructions carefully before using the refrigerator. STARTING THE REFRIGERATOR .................
OPERATING INSTRUCTIONS CONTROLS 2. Set the thermostat knob (E) to the highest setting. 3. Turn the energy selector (A) to position “GAS”. 4. Push the button (D) in until it reaches the bottom and hold, push the button (C) for the piezo igniter several times to light the burner. This can be observed on the flame indicator (B), on the refrigerator. When the flame is on, the red indicator is in the green field. 5. After the gas is lit keep the button (D) pressed for 10 seconds.
Most kinds of frozen food can be stored in the frozen food compartment for about a month. This period of time may vary, however, and it is important to follow the instructions on the individual packages. The cooling unit behind the refrigerator should be cleaned with a brush from time to time, but make sure that the refrigerator is switched off when doing this.
MAINTENANCE DOOR PANEL Always turn to a qualified service technician who is familiar with LP gas systems and refrigerator. We recommend that a service technician check the refrigerator once a year. • Check all connections in the LP gas system for gas leaks. Connections can be tested for leaks using a soap solution. Do not use a naked flame! If there is any suspicion of damage, call for a service technician. Door panels can easily be fitted or changed.
A length of sealing strip is applied to the rear surface of the front frame for this purpose, see fig. 2. Note: A wood strip must be in place across the upper opening of the enclosure. The top frame of the refrigerator will be anchored to the wood strip with screws. See fig. 6 b. Push the refrigerator into the recess until the sealing strip on the flange seals against the front of the recess, so that the cooling unit is completely sealed off against the interior of the caravan.
VENTILATION OF THE UNIT NOTE: Wood Strip MUST be in place Minimum ventilation height Condenser FIG. 6a FIG. 6b Ventilation heights Model Minimum ventilation heights in mm. Installation with upper and lower side vent. RM 4601 1760 Minimum ventilation height Installation with roof vent and lower side vent. 1515 At extreme ambient temperatures the refrigeration unit will only perform adequately when properly ventilated.
The supply pipe should preferable be of copper. If any other material is used, it must be of a type approved for use with continuously operating bottled-gas appliances and have threaded connections throughout. All connectors etc. should be of a type specifically designed for the type and diameter of the connection pipe used, and screwed joints should be sealed with a joining compound approved for use with bottled-gas.
1 1 1 2 3 3 1 1 1 4 5 FIG.
OPERATING AND INSTALLATION INSTRUCTIONS FOR DOMETIC REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: OPERATING INSTRUCTIONS .......................... 12 CONTROLS .................................................. 12 STARTING THE REFRIGERATOR ............... 12 It is important to read through these instructions carefully before using the refrigerator.
OPERATING INSTRUCTIONS CONTROLS 3. Turn the energy selector (A) to position “GAS”. A ticking sound will be heard and the lamp (B) will start flashing. 4. Push the button (C) in until it reaches the bottom and hold. This opens the flame failure device and allows gas to flow to the burner. 5. When the flame lights, the sparking stops automatically and the lamp stops flashing. 6. Hold the button (C) an additional 10-15 seconds to activate the flame failure device, then release it.
Most kinds of frozen food can be stored in the frozen food compartment for about a month. This period of time may vary, however, and it is important to follow the instructions on the individual packages. The cooling unit behind the refrigerator should be cleaned with a brush from time to time, but make sure that the refrigerator is switched off when doing this. ICE MAKING If the refrigerator is not to be used for some time: 1. Set the switch (A), fig. 1, to “OFF”. 2.
MAINTENANCE DOOR PANEL Always turn to a qualified service technician who is familiar with LP gas systems and refrigerator. We recommend that a service technician check the refrigerator once a year. • Check all connections in the LP gas system for gas leaks. Connections can be tested for leaks using a soap solution. Do not use a naked flame! If there is any suspicion of damage, call for a service technician. Door panels can easily be fitted or changed.
A length of sealing strip is applied to the rear surface of the front frame for this purpose, see fig. 2. Note: A wood strip must be in place across the upper opening of the enclosure. The top frame of the refrigerator will be anchored to the wood strip with screws. See fig. 6 b. Push the refrigerator into the recess until the sealing strip on the flange seals against the front of the recess, so that the cooling unit is completely sealed off against the interior of the caravan.
VENTILATION OF THE UNIT NOTE: Wood Strip MUST be in place Minimum ventilation height Condenser FIG. 6a FIG. 6b Ventilation heights Model Minimum ventilation heights in mm. Installation with upper and lower side vent. RM 4601 1760 Minimum ventilation height Installation with roof vent and lower side vent. 1515 At extreme ambient temperatures the refrigeration unit will only perform adequately when properly ventilated.
The supply pipe should preferable be of copper. If any other material is used, it must be of a type approved for use with continuously operating bottled-gas appliances and have threaded connections throughout. All connectors etc. should be of a type specifically designed for the type and diameter of the connection pipe used, and screwed joints should be sealed with a joining compound approved for use with bottled-gas.
TECHNICAL DATA RM 4601 Overall dimensions, refrigerator Height (incl. controls) ......................... 1427 Width ................................................. 632 Depth (incl. handle) ........................... 668 Recess dimensions Height ................................................ 1415 Width ................................................. 607 Depth ................................................. 620 Capacity Gross ................................................. 186 Net ................
Wiring diagram RM 4601 with reigniter 19
Positioning of shelves 20 MO-M 0540