DOMETIC GMBH TECHNICAL DOCUMENTATION SERVICE MANUAL SIEGEN DOMETIC ABSORTIONREFRIGERATOR for LEISURE VEHICLES the new 8 series RM 8XXX TD MBA 2007-10 EN –
Content Page MODELS TD S3 OPERATING TD S21 COMPONENTS TD S32 INSTALLATION TD S39 SERVICE + MAINTENANCE TD S46 TD S2
MODELS TD S3
MODELS Description of models L = with interior light RM(S)(T) 8400 L RM Refrigerator Mobile S = housing with step T = TecTower D = large L = extra Large O = single-door fridge with oven TD S4 series 0 = manual ignition (battery igniter) 1 = Automatic ignition 5 = Automatic ignition and automatic energy selection 4 = width 486 mm 0 = Standard Depth 5 = width 525 mm 5 = Depth + 55 mm 6 = Depth + 65 mm
MODELS Model Description TD S5 RM(S)8xx1 MES 85-122 l RM(S)8xx5 AES 85-122 l Width of Housing: 486 mm or 525 mm Height: 821 mm Depth: 568mm, 623mm or 633mm Fridges of the 8-series are only available with curved door
MODELS Model Description TD S6 RM(S)8xx0 Battery Igniter 85-122 l Width of Housing: 486 mm or 525 mm Height: 821 mm, Depth: 568 mm, 623 mm or 633 mm Fridges of the 8-series with manual ignition are provided with a battery igniter and a Gas-Operation-Indicator (Galvanometer)
MODELS Special Features RM 8xxx The housing of the fridge RM 8xxx consists of absolute plastic material (Polystyrene) and is equipped with carrying handles on the side. Due to this a decrease of weight of ca. 1.5 kg is achieved compared to similar models like RM 7401 or RM 7405. There is a continuous groove on the outsides and bottom part. A flexible sealing has to be fitted into this groove, in order to enable an airtight assembly.
MODELS Special Features RM 8xxx Building in the fridge, please note, that the feet are not screwed onto the housing anymore, but are injected directly onto it. Thus, when building in the fridge, it is not possible anymore to save 8mm height by taking off the feet.
MODELS Special Features RM 8xxx The color of the inner liner is not papyrus white anymore, but white. The shelves and the vegetable bin are ice-blue. An innovative shelf system enables individual usage of the cooling compartment. The shelves and the bin are dishwasher-suitable. The vegetable bin is available with and without lid. The rubber sealing is exchangeable.
MODELS Special Features RM 8xxx In all single-door RM 8xxx fridges, the freezing compartment can be taken out if needed. This increases the capacity as well as the cooling performance in the cooling compartment.
MODELS Special Features RM 8xxx RM 8xxx with removable freezer compartment TD S11 Locking of freezing compartment
MODELS Special Features RM 8xxx All RM 8xxx fridges have a new door lock. By pushing the locking button the door is opened. Closing the door the locking bar snaps in and the door is locked. For using the locking button, the panel is formed asymmetric (recess on one side). I.e. changing the door rabbet is not possible anymore. The rabbet has to be determined before the fridge is installed. The product number controls the side of the door rabbet.
MODELS Special Features RM 8xxx The locking bar inside the door is fixed with two screws, which are behind a plastic cover. The gear rods inside the door are not exchangeable. The lock in the fridge is exchangeable. It also contains the fridge lighting, which was converted into a long-living LED-lighting. The door is brought into winter position by moving the red hook.
MODELS Special Features RM 8xxx TD S14 Purchasing an RM 7xxx or an RM 8xxx, there is the option of an electrical doorlock. When the fridge door is closed, it is kept shut by a magnetic sealing, but not locked. Starting the engine, the electronics will automatically lock the fridge door, due to the recognition of the D+ signal. Also with this kind of door lock, changing the door rabbet is not possible.
MODELS Special Features RM 8xxx All RM 8xxx fridges are equipped with new door hinges made of metal with a plastic casing (polystyrene). This hinges are not screwed onto the housing anymore, but snap in. Thus it is not necessary anymore to adjust the height. Building in the fridge, please note, that the door hinges have to be supported. Minimum requirement for the supporting surface of the lower hinges is the distance from the housing edge to the outer edges of the hinges with 40mm.
MODELLE Special Features RM 8xxx Changing the decor plate, the door has not to be demounted anymore. It can be changed easily: Loosen the plastic ledge on the locking side carefully. This ledge is only snapped in, but not screwed onto the housing. Then pull out the decor plate and put in the new one. After this reattach the plastic ledge.
MODELS Special Features RM 8xxx The operation panel can be loosened with two screws, when the door is opened. The electronics at the RM 8xx1 and RM 8xx5 is screwed into the panel from the inside. If the fridge is demounted, the operation panel including the holding device can be loosened very easily. It is only attached to the housing.
MODELS Special Features RM 8xxx If the fridge is equipped with a battery igniter, as with the 7xxx – generation, a V85 Gas / electro fitting and the known energy-selection switch are used. Also, the RM 8xxx fridges are equipped with a galvanometer, which indicates if the flame is burning. At all single-door fridges of the 8-series, the main connecting block is positioned on the top of the housing. The electronics is screwed into the panel.
MODELS Special Features RM 8xxx On the backside of the 8-series fridges the same components are used as with the 7xxxGeneration. Cooling unit, gas valve GV 100, burner control device P810, burner and heating elements are identical. The cooling unit and the components are screwed onto a metal sheet plate, which is fixed onto the back side of the plastic housing.
MODELS Special Features RM 8xxx MES Electronics AES Electronics Optical differentiation: a “BEEPER“ TD S20 The electronics were completely renewed. Instead of using a semiconductor, as with AES III or MES, the new generation uses a microprocessor. The AESmodels are equipped with a 7-segment-display. If an error occurs, there is an acoustic signal. There is no acoustic signal for the MES-models. All optical indications are shown with LED.
OPERATION TD S21
OPERATION Interior light If the door is left opened, the lighting switches off automatically after 2 minutes. Dimming function of the indications on the operation panel 10 seconds after the button has been pushed for the last time, the indication (LED) switches into the dim-mode. The dim-mode is reversed by pushing a button. The desired function is activated by pushing the button again.
OPERATION 1 2 3 4 230 V 12 V GAS Mode on/off MES Temp 5 6 door 7 Description of the Display: 1. 2. 3. TD S23 Pushing the button ON/OFF and modeselection-button longer than 2 seconds = ON/OFF Pushing the button <2 Seconds = Selection next Mode (230V, 12V, GAS, Auto) LED Fault indication LED Mode-Indication 4. 5. 6. 7. 5-step LED-Indication for inner temperature selection (5 LEDs = max.
OPERATION 230V-Operation mode (AC-Mode) The 230V-operation mode is selected by pushing the button 1 (see TD S23). The button has to be pushed several times, until the LED next to the Symbol of the power plug lights up. Detection of undervoltage while operating with 230V The controlling electronics is equipped with a detection of undervoltage. Conditions: - limit value: 195 V AC (min. 188 V, max. 202V) - The 230V-Relais switches off after ca.
OPERATION 12V-operation mode (DC-Mode) The 12V-operation mode is selected by pushing the button 1 (see TD S23). The button has to be pushed several times, until the LED next to the Symbol of the battery lights up. Detection of undervoltage while operating with 12V The controlling electronics is equipped with a detection of undervoltage. Conditions: - Limit value: 10.5 V AC (min. 10.2 V, max. 10.
OPERATION Gas-operation mode The 12V-operation mode is selected by pushing the button 1 (see TD S23). The button has to be pushed several times, until the LED next to the Symbol of the Gas lights up or the (AES-) display indicates GAS. Ignition while operating with gas. The controlling electronics initiates max. 3 ignition attempts in the following cycle: 25 sec. ignition, if not ok, 2 min. ventilation break 25 sec. ignition, if not ok, 2 min. ventilation break 25 sec.
OPERATION 1 2 3 4 Mode ON/OFF Temp door AES 5 Description of the Display: 1. Pushing the button ON/OFF and Mode-selection-button longer than 2 seconds = ON/OFF Pushing the button <2 Seconds = Selection next mode (230V, 12V, GAS, Auto) 2. LED Fault indication 3. Segment Mode-Indication: GAS = Gas mode 12 = 12 V DC Mode 230=230 V AC Mode Selecting the automatic mode, the display shows AU alternating Gas, 12 or 230 (AU = automatic mode) TD S27 6 4. 5. 6. 7.
OPERATION 230V-operation mode (manual) The 12V-operation mode is selected by pushing the button 1 (see TD S27). The button has to be pushed several times, until the 7-segment-display indicates 230. Detection of undervoltage while operating with 230V The controlling electronics is equipped with a detection of undervoltage. Conditions: - Limit value: 195 V AC (min. 188 V, max. 202V) - 230V-Relais switches off after ca.
OPERATION 12V- operation mode (manual) The 12V-operation mode is selected by pushing the button 1 (see TD S27). The button has to be pushed several times, until the 7-segment-display indicates 12V. D+ or S+ is not taken into account in the manual mode. Detection of undervoltage while operating with 12V The controlling electronics is equipped with a detection of undervoltage. Conditions: - Limit value: 10.5 V AC (min. 10.2 V, max. 10.8 V) - 12V-Relais switches off after ca.
OPERATION Gas-operation mode (manual) The gas operation mode is selected by pushing the button 1 (see TD S27). The button has to be pushed several times, until the 7-Segment display indicates GAS. Ignition while operating with gas The controlling electronics initiates max. 3 ignition attempts in the following cycle: 25 sec. ignition, if not ok, 2 min. ventilation break, 25 sec. ignition, if not ok, 2 min. ventilation break, 25 sec.
OPERATION Automatic Mode The automatic mode is selected by pushing the button 1 (see TD S27). The button has to be pushed several times, until the 7-segment display indicates AU. The display switches from AU to the current energy mode every 10 seconds. - Priority 12V-Solar 230V 12V (D+) Gas - Refueling stop of 15 minutes while operating in Auto-12V-Mode (i.e. the electronics system switches into gas mode only after 15 minutes).
COMPONENTS TD S32
COMPONENTS Electronics POWER MODULE MES X 105 Fuse 1A (250V) Fuse for burner control device TD S33 X 114 X 108 X 110 Connection to Display X 111 Contacts X 109 J4 / J5 J1/ J2 X 102 X 101 X105 = 12 V Supply / - Wiring Recognition of heating element X114 = Reed switch or alt. electr. lock X108 = Temperature sensor (NTC) X110 = Connection burner control device (+/-, failure) X111 = alt. 2. electr.
COMPONENTS Electronics POWER MODULE AES X 105 Fuse 1A (250V) X 114 X 108 X 110 RF Module for RMCD remote control X 111 J4 / J5 X 106 TD S34 Contacts X 109 Connection to Display X105 = 12 V Supply / - Wiring Recognition of heating element X114 = Reed switch or alt. electr. lock X108 = Temperature sensor (NTC) X110 = Connection to burner control device (+/-, failure) X111 = alt. 2. electr.
COMPONENTS Burner Control Device P810 includes Igniter ( 20-30 sec.) Flame control and Flame failure device Gas valve control (stops ignition and gas input in case of gas fault) Power supply : approx. 1.
COMPONENTS Gas (Safety)-Valve GV100 includes 2 serial mounted gas valves Power supply: approx. 1.3V - 1.5V per valve (if switched on approx.
COMPONENTS Gas Burner Device Already installed Igniting electrode (1) 2 3 Ionization electrode (2) and ground contact (3) on burner chassis TD S37 1
COMPONENTS Temperature sensor (NTC) Installed at lower reevaporator All operation modes (DC/AC/GAS) are controlled thermostatically.
INSTALLATION TD S39
INSTALLATION Scheme of connecting points 230V-wire – connection to electronics Connection power supply 12VDC D+ and S+ Signal 12VDC Power supply Heating element Gas supply TD S40
INSTALLATION Electrical Installation First of all, please note the INSTALLATION INSTRUCTIONS. Some important points: Power line connection protection with a 2A fuse Battery connection protection with a 16A fuse The electric circuit of the 12V-heating element has to be switched via an appropriate relay, so the heating element is not supplied anymore, after the engine has been turned off. The electronics has to be permanently attached to 12V, which is not interrupted, turning off the engine.
INSTALLATION Electrical Installation Terminal block AES-Model 1 black: - cable 12V-permantent connection for electronics 2 violet: + cable 12V-permanent connection for electronics 3 bl: 4 wt: D+ cable to contact X106 on the electronics S+ cable to contact X106 on the electronics 5 white: 6 red: -cable for 12V heating element + cable for 12V heating element via starter lock and 16A fuse At the terminal strip of the MES-models, the terminals 3 + 4 are not used.
INSTALLATION Electrical Installation TD S43
INSTALLATION Electrical Installation TD S44
INSTALLATION Gas installation First of all, please note the information of the INSTALLATION INSTRUCTIONS. The gas connection to the appliance has to be done with a cutting ring connection L8, DIN 2353-ST acc. to EN 1949 (e.g.. Ermeto). Burner control device (1) 1 2 Gas connection (3) A Gas tube to the burner (4) B 3 4 TD S45 Gas valve (2) A (max. torque 10Nm ) and B (max.
SERVICE + MAINTENANCE TD S46
SERVICE + MAINTENANCE INSTALLATION Some information Gas Valve GV100 Masse This component includes two serial mounted gas valves (as part of flame failure device). 1 Power supply : approx. 1.3V - 1.5V per valve Power supply : approx. 0,7V - 0,9V per valve (switched on gas mode) Inductive resistance : per valve ca.
SERVICE + MAINTENANCE INSTALLATION Some information Burner Control Device P810 1 2 Power Supply: ca. 1.3V Measuring points: Flat plug connection between Pin 2 and Pin 3. Cable to Ignition plug : 1 Cable to ionization plug : 2 Exchanging the cables is not possible, as they have different dimensions.
SERVICE + MAINTENANCE INSTALLATION Some information Temperature Sensor (NTC) Table of resistance Temperature °C Resistance kOhm 0 5 10 15 20 25 27.7 22.29 18.07 14.74 12.11 10.00 Measuring Point: Electronics loosen contact X108 Cable white / brown When the sensor is defect, the fridge will operate permanently.
SERVICE + MAINTENANCE INSTALLATION Some information Interior light and door lock The Interior light and the door lock are unit, which is exchanged completely in case of a defect. The transparent cover is not included, but a separate part. After removing the cover, the lighting housing can be dismantled.
SERVICE + MAINTENANCE INSTALLATION Some information Cleaning of burner The burner and the chimney must be cleaned regularly, at least one time a year. If auto gas is used, Dometic recommends a maintenance every half year, as the contamination risk of the burner is higher, due to the burning of the auto gas.
SERVICE + MAINTENANCE Service Mode AES The Service Mode is activated by keeping pressed down the temperature button and switching on the main button. After this the 7-Segment-Display shows „1“.
SERVICE + MAINTENANCE Service Mode AES 8 = Intern test step (is not indicated) 9 = Recognizing electrical lock or reed switch 10 = activates all 7 segment-components one after the other 11 = activates all LED´s Exiting the diagnosis mode: Push „mode“ button or wait for 10 minutes.
SERVICE + MAINTENANCE Controlling the interior light via reed switch The AES-Electronics uses the X114 and X111 as well for controlling the reed switch as well as the electrical lock. The electronics will recognize the application of a reed switch, following the below steps: 1. Choose step 9 in the service mode 2. Open the door 3. Close the door (reed switch will be recognized) 4. Continue service mode (push button 6) The interior light will now be controlled via the reed switch.
SERVICE + MAINTENANCE Electrical door lock Optionally, 2 electrical door locks can be controlled. They are connected to X111 and X114 (it does not matter in which order; X111 and X114 are equivalent) In the service mode the electronics will recognize the locks, following the below steps: 1. Open the door(s) 2. Choose step 9 in the service mode 3. Close door(s) (Door locks will be recognized) 4. Activate D+ 5.
SERVICE + MAINTENANCE No. Failure AES 1 No 230V, respective under 195V (AC Mode) Failure LED 2 and „230“ (3) flash Acoustic Signal 2 No 12V, respective under 10,5V (DC Mode) Failure LED 2 and „12“ (3) flash Acoustic Signal 3 Ignition without success (Gas Mode) Failure LED 2 and „GAS“ (3) flash Acoustic Signal 4 NTC sensor defect Failure LED 2 and Temp.
SERVICE + MAINTENANCE *Sequence for recognizing „Heating element defect“: Conditions: Interior temperature >18°C, corresponding relay is switched on (230V or 12V), door has to be closed for longer than 5 minutes.
SERVICE + MAINTENANCE Service Mode MES The Service Mode is activated by keeping pressed down the temperature button and switching on the main button. After this all 3 mode-LEDs (3) light up.
SERVICE + MAINTENANCE Service Mode MES 7 = Recognition sequence (Reed switch or electrical lock) 8 = activates temperature LEDs (4) 9 = activates lock and failure LED (2) + (5) Exiting the diagnosis mode: Push the „mode“ button or wait for 10 minutes.
SERVICE + MAINTENANCE Controlling the interior light via reed switch The MES-Electronics uses the X114 and X111 as well for controlling the reed switch as well as the electrical lock. In the Service mode, the electronics will recognize the application of a reed switch, following the below steps: 1. Choose step 7 in the service mode 2. Deactivate D+; open the door 3. Push temperature button (6) 4. Close the door (reed switch will be recognized) 5.
SERVICE + MAINTENANCE Electrical door lock Optionally, max. two electrical door locks can be controlled. They are connected to X111 and X114 (Notify, that if there is only one lock this has to be connected to X111). In the service mode the electronics will recognize the locks following the below steps: 1. Open the door(s) 2. Choose step 7 in the service mode 3. Close the door(s) 4. Deactivate D+ 5.
SERVICE + MAINTENANCE Error messages No.
SERVICE + MAINTENANCE *Sequence for recognizing „heating element defect“: Conditions: Interior temperature >18°C, corresponding relay is switched on (230V or 12V), door has to be closed for longer than 5 minutes Temperature of reevaporator (a) is recorded After 2 hours, the temperature (b) is recorded again, if the fridge is in the same mode. If the temperature difference a-b < 3 °K, the corresponding heating element error will be indicated.
INSTALLATION DOMETIC GMBH TECHNISCHE DOKUMENTATION IN DER STEINWIESE 16 D-57074 SIEGEN GERMANY www.dometic.