Installation Instructions

13
Correct mounting of the lower ventilation grille
facilitates access to the connections and
functional parts during maintenance.
Fig. 17
ventilation grille LS 100 or LS 200
ventilation grille LS 200
2
1
The ventilation grilles must have an open
cross-section of at least 250cm². This is
achieved by using the Dometic L100 / L 200
absorber ventilation and air extraction system
which has been tested and approved for this
purpose.
Fig. 19
Fig. 20
The LS 100 upper vent system kit consists of
the mounting frame (RS 1640), the air grille
including flue gas duct (AS 1620) and the winter
cover (WA120). The LS 200 lower vent system
kit consists of the mounting frame (RS 1650),
the air grille (AS1 630, but without flue gas duct)
and the winter cover (WA130).
4.3 Installing the ventilation system
LS 100
LS 200
Installation
Fig. 18
ventilation aperture
(d = 20 - 40 mm)
ventilation aperture
1
2
1
2