G. LP gas pressure low at burner.
Set main regulator so pressure does not drop below
11 inches of water column at pressure test port (See
FIG. 9).
H. Burner not located properly under flue tube.
Relocate
I. Burner damaged.
Replace
J. Odor from fumes.
1. Dislocated burner
2. Damaged burner
3. Dirty flue tube
K. FUSES
1. Refrigerator control system
2. Refrigerator AC Supply
See section Maintenance & Service, item 3.
Periodic Maintenance, Paragraph F.
NOTE: AVOID SPRAYING WATER THROUGH THE
REFRIGERATOR VENTS WHILE WASHING YOUR
RV.
All the above instructions are to be followed closely. The
refrigerator is quality-guaranteed. However, we are not
responsible for any failures caused by improper adjust-
ments and unfavorable installation conditions. Contact
service point or distributor service dept. for assistance.
SPARE PARTS
The following list is a list of commonly used parts, which
should be available, if required, from your Dometic Ser-
vice Center.
Part No. Description
17 37 71-02/3 Heater, 175W, 120V
200 22 61-24/2 Door shelf, 3 pieces
200 71 72-02/2 Baffle
200 74 19-15/9 Jet, No.39
293 27 81-01/2 Electrode
293 06 97-07/9 Burner
293 20 52-01/8 Thermocouple
293 26 36-01/8 Box
293 11 32-02/7 Spark ignition device
Hinge Kit from right to left and left to right
385 03 04-01/9 (light brown)
Hinge Kit from right to left and left to right
385 03 04-02/7 (black)
Contact an authorized service center for