peRioDic MaiNteNaNce

Check the control system by connecting/disconnecting the


Check all connections in the LP gas system (at the 1.
back of the refrigerator) for gas leaks. The LP gas
supply must be turned on.
2.
connections. The appearance of bubbles indicates a
leak and should be repaired immediately

The LP gas pressure should be checked and the main regulator
readjusted if pressure is incorrect. The correct operating pres-
sure is 11 inches of water column. Measure the LP gas pressure
at the test port, just ahead of the burner jet.


of soot. Heavy soot formation indicates improper functioning
of the burner.

Turn off the refrigerator. 1.
2.
Disconnect the wires or shut off the 12V DC power
supply to the refrigerator.
Turn off the manual shut off valve.3.
Remove cover from burner housing. Remove the 4.
burner mounting screws and then, the burner as-
sembly.
5.

-6.
not properly

7.
Clean the burner tube with a brush. Blow out the 8.
burner with compressed air.
9.

Remove the burner jet. 10.
Soak the jet in wood alcohol and blow it out with 11.
compressed air.
R12. einstall and tighten the burner jet.
13.
into the slot on the burner bracket. Verify that the
-
couple is positioned properly (tip of thermocouple
extends over two slots of burner).
Check the electrode for proper location and gap. 14.
Turn on the manual gas shut off valve. 15.
16.
non-corrosive bubble solution.)
Connect the 120V power cord. Reconnect/turn on 17.
the 12V DC power.
Check the LP gas safety shut off. 18.
BURNER TUBE .
SPARK ELECTRODE
BURNER JET
BURNER MOUNTING
SCREWS
PRESSURE TEST PORT
MANUAL SHUT OFF VALVE
(Shown in open position)
INLET FITTING
SOLENOID VALVE
