geNeRal iNfoRMatioN
Ventilation is one of the requirements for proper cooling unit
operation. The installation should be made in such a manner as
to separate the combustion system from the living space of the
mobile home or recreational vehicle. Openings for air supply
or for venting of combustion products should have a minimum
dimension of not less than 1/4 inch.
Proper installation requires one lower fresh air intake and
roof vent and one lower side vent. The ventilation kits shown
.
The ventilation kits must be installed and used without
in the refrigerator compartment has to be provided for
ventilation of heavier-than-air fuel gases. The lower vent
of the recommended kits is provided with proper size
not be obstructed.
an adequate access opening for ready serviceability of the
burner and control manifold of the refrigerator. This should
be centered on the back of the refrigerator.
Model
Kit
No.
Components Part no.
RM2351
RM2354
Roof Base
Roof Cover
Lower Side Vent
Lower Side Vent
Upper Side Vent
Lower Side Vent
Upper Side Vent
Upper Side Vent
Lower Side Vent
Lower Side Vent
3103633.XXX* or 3310893.XXX*
3103634.XXX* or 3310894.XXX*
3109350.XXX*
RM183
RM183
3108705.751**
3109492.003
RM183
3109492.003
RM2451
RM2454
RM2551
RM2554
Roof Base
Roof Cover
Lower Side Vent
3103633.XXX* or 3310893.XXX*
3103634.XXX* or 3310894.XXX*
3109350.XXX*
DM2652
DM2662
DM2663
DM2852
DM2862
DM3862
NDM1062
Roof Base
Roof Cover
Lower Side Vent
3103633.XXX* or 3310893.XXX*
3103634.XXX* or 3310894.XXX*
3109350.XXX*
NDR1292 Roof Base
Roof Cover
Lower Side Vent
3103633.XXX* or 3310893.XXX*
3103634.XXX* or 3310894.XXX*
3103649.XXX*
3108705.744**
* Replace “XXX” with the color code numbers. For color codes,
contact your supplier.
** Alternate instructions forwarded with the Ventilator Kit.
For further information, contact your dealer or distributor.
(latest edition).
Manufactured Home Construction and Safety Standard, Title
24 CFR, Part 3280.
If an external electrical source is utilized, the refrigerator, when
installed, must be electrically grounded in accordance with
local codes or, in the absence of local codes, the National Elec-
and Mobile Housing.
If an external electrical source is utilized, the refrigerator,
when installed, must be electrically grounded in accordance
with local codes or, in the absence of local codes, the Canadian
certification and code requirements
Ventilation requirements
CAUTION
-
installation instructions