REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION RM2500 RM2400 RM2300 RM2800 RM2600 FOR YOUR SAFETY If you smell gas: 1. Open windows. 2. Don’t touch electrical switches. 3. Extinguish any open flame. 4. Immediately call your gas supplier. Installation Instructions for use Gas equipment Electric equipment Maintenance Fault tracing Door panel FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
REFRIGERATORS WITH PIE20 IGNITER RM2300/2400 -36 @;:aq\ 39 Fig.1 E DCB A Item No.
REFRIGERATORS WITH AUTOMATIC IGNITION RM2500 Fig.2 Item No.
REFRIQERATORS WITH AUTOMATIC IQNITION RM2600 RM 2800 Fig.3 Item No.
INSTALLATION GENERAL INSTRUCTIONS This appliance is designed for storage of foods and storage of frozen foods and maklng ice. The refrigerators outlined hereon have been design certified under ANS 221.19 -- 1983. Refrigerators by the American Gas Association for installation in a mobile home or recreational vehicle and are appproved by the Canadian Gas Association. The certifications are, however, contingent on the installation being made in accordance with the following instructions as applicable.
SPECIAL HINTS Note. Do not install the appliance directly on carpeting. Carpeting must be protected by a metal or wood panel beneath the appliance which extends at least full width and depth of the appliance. The refrigerator must be installed in a substantial enclosure and must be level. A spirit level is supplied with each refrigerator and by placing it in the freezer compartment one can level the refrigerator both ways front to back and side to side.
CERTIFIED INSTALLATION Certified installations require one roof vent and one lower side vent or as optional one upper vent and one lower side vent. The two alternatives are provided for by using the different kits listed in the Appendix. For further information contact your dealer or distributor. METHODS OF INSTALLATION Condenser The methods of installation are shown in figures 10 a and 10 b.
CLEARANCES Minimum clearances in inches to combustible materials are G. Top 0 K.
INSTRUCTIONS FOR USE HOW TO START THE REFRIGERATOR Leveling In the boiler, ammonia vapor is distilled from an ammonia-water mixture and carried to the finned condenser, where it liquifies. The liquid flows to the evaporator, where it creates cold by evaporating into a circulating flow of hydrogen gas. If the evaporator coil is not level the liquid readily accumulates, forming pockets which can impair the gas curculation or even block it, in which case, of course, the cooling will stop.
Frozen Food Storage Compartment The Flame Failure Safety Device The ice trays should be placed in direct contact with the freezer shelf for fastest ice making. Quick frozen soft fruits and ice cream should be placed in the coldest part of the compartment which is at the bottom of the aluminium liner or, in models with a shelf, on this or just below it. Frozen vegetables, on the other hand, may be stored in any part of the compartment.
INSTRUCTIONS FOR MOUNTING THE DOOR PANEL The refrigerator is normally delivered without door panel(s). Before starting the mounting work check that the panel dimensions are in compliance with those given in the table and read the instructions through. When mounting the panel, proceed as follows. A. Remove the door decoration list (2) with its two screws (1). The upper corners of the upper panel (2door models) and the lower comers of the lower panel has to be cut according to the sketch. B.