ELECTRICAL CONNECTION
120 V AC CONNECTION
plug for your protection against shock hazards and should be
plugged directly into a properly grounded threeprong recep-
tacle. Do not cut or remove the grounding prong from this
plug.
The free length of the cord is 2 feet and
it is recommended that the receptacle is
located to the left of the refrigerator
access through the vent door. The cord
should be routed to avoid direct contact
other components that could damage the
cord insulation.
12 V DC CONNECTION (RM2510)
power for operation of the automatic reigniter. The connection
NOTE!
Do not use the chassis or vehicle frame as one of the
120 Volt AC
receptacle
6”
INSTALLATION INSTRUCTIONS
TESTING LP GAS SAFETY SHUTOFF
The gas safety shutoff must be tested after the refrigerator is
RM2410
To test the gas safety shutoff, proceed as follows:
Turn on the refrigerator.
-
to the burner jet. Be careful not to damage the burner
jet.
burner jet. Bubbles indicate a defective gas safety
shutoff and service is required.
If no bubbles were present at the burner jet, rinse the
-
.
RM2510
To test the gas safety shutoff, proceed as follows:
Turn on the refrigerator.
out.
-
should not be sparking.
to the burner jet. Be careful not to damage the burner
jet.
burner jet. Bubbles indicate a defective gas safety
shutoff and service is required.
If no bubbles were present at the burner jet, rinse the
2.
6.
7.
8.
2.
6.
7.
8.