Replace the top decoration panel.
Make sure the tabs snap back into the holes in the hinge
plate.
STEP 3: Two screws installed in the rear base.
See FIG. 10.
Failure to follow the sequence in securing the refrigerator
in the enclosure can cause leakage between the frame
and cabinet. Any space between the counter, storage
area or ceiling and top of the refrigerator greater than
1-1/2 inches should be blocked. The heat produced at
the rear of the refrigerator will become trapped in this
space, making the top of the refrigerator hot and reduce
the efficiency of the refrigerator.
GAS CONNECTION
Hook up to the gas supply line is accomplished at the
manual gas valve, which is furnished with a 3/8" SAE
(UNF 5/8" -18) male flare connection. All completed con-
nections should be checked for leaks with soapy water.
FIG. 9
DO NOT use a flame to check for gas leaks.
The gas supply system must incorporate a pressure
regulator to maintain a supply pressure of not more than
11 inches water column.
When testing the gas supply system at test pressures in
excess of 1/2 psi, the refrigerator and its individual shutoff
valve must be disconnected from the gas supply piping
system.
When testing the gas supply system at pressures less
than or equal to 1/2 psi, the appliance must be isolated
from the gas supply piping system by closing its indi-
vidual manual shutoff valve.
In case detailed instructions on the installation and con-
nection to the gas supply are required, contact your
dealer or distributor.
TESTING LP GAS SAFETY SHUTOFF
The gas safety shutoff must be tested after the re-
frigerator is connected to the LP gas supply.
To test the gas safety shutoff, proceed as follows:
1. Start the refrigerator according to the instructions for
Gas Operation. See section Operating Instructions.
2. Check that the gas flame is lit. This can be observed
on the flame indicator E. The red indicator is in the
green field, (ON).
3. Close the gas valve by turning the knob A back to
OFF position.
4. Wait for one minute.
5. Remove protection cover (see FIG. 1). Open the gas
valve by turning knob A to position GAS without
pushing the buttons C and D. Apply a non-corrosive
commercial bubble solution to the burner jet.
6. No bubbles should appear at the opening of the
burner jet. The presence of bubbles indicates a de-
fective gas safety shutoff, and service is required.
7. If no bubbles were present at the burner jet, the gas
safety valve is working properly. Rinse jet thoroughly
with fresh water before proceeding. Be careful not to
damage the burner jet.
Replace the protection cover and turn the main switch
OFF and back ON. See instruction for Gas Opera-
tion , section Operating Instructions. Normal opera-
tion of the burner should return. Allow the burner to
operate for a minimum of 5 minutes.
1
2
Drain water hose
A hole must be drilled through flooring see FIG. 10.
The installer MUST make sure that the hose does not
kink when run through the floor. Seal around the hose
that goes through the drilled hole. If a longer hose than
supplied is required to get the water to drain outside of
the vehicle, the installer will have to supply the extra
length of hose.
! WARNING
FIG. 10
Hole for drain water hose