User manual

- 10 -
PRODUCT CARE
CAUTION
!
CAUTION
!
CLEANING
Always keep the refrigerator clean. Cleaning the refrigerator
is usually done after it is defrosted or put into storage. Use
lukewarm weak soda solution to clean the interior liner of the
refrigerator. Use warm water only to clean the fi nned evapora-
tor, gasket, ice tray and shelves.
Never use strong chemicals or abrasives to clean
these parts, as the protective surfaces will be
damaged. Do not spray liquids near elctrical outlets,
connections or the refrigerator components.
To keep the refrigerator operating effi ciently and safely, peri-
odic inspection and cleaning of several components once or
twice a year is recommended:
Check the lower vent, upper vent and area between these
openings for any obstructions such as bird/insect nests,
spider webs, etc.
Make sure the refrigerator area is free from combustible
material, gasoline and other fl ammable vapors or liquids.
Clean the coils on the back of the refrigerator. Use a soft
bristled brush to dust off the coils.
•
•
•
CAUTION
!
DEFROSTING
Shut off the refrigerator. (Press the ON/OFF button
to the OFF position.)
Empty the refrigerator.
Leave the cabinet and freezer doors open and place
the drip tray under the fi nned evaporator.
Defrosting time can be reduced by fi lling the ice
trays with hot water and placing them in the freezer
compartment.
Do not use:
A knife or an ice pick, or other sharp tools to
remove frost from the freezer shelves. It can
create a leak in the ammonia system.
A hot air blower. Permanent damage could result
from warping the metal or plastic parts.
When all the frost has melted, dry the interior with a
clean cloth and put the food back.
Turn the refrigerator back on.
REPLACING THE HALOGEN LAMP
RM3862 & NDR1062
Before replacing the lamp, turn off the refrigerator.
Wear gloves as protection against hot lamp, broken
glass ans as protection of the new lamp.
The lamp is located at the top of the refrigerator compartment.
To replace the lamp, follow these steps:
Remove the lamp cover.
Wearing gloves, pull out the lamp from socket. Re-
place it with a new 12V, 10W halogen lamp base G4.
Put back the lamp cover.
1.
2.
3.
•
•
4.
5.
1.
2.
3.