User manual
14
H. LP gas pressure low at burner.
Set main regulator so pressure does not drop
below 11 inches of water column at pressure test
port. (See FIG. 12).
I. Burner not located properly under flue tube.
Relocate.
J. Burner damaged.
Replace.
K. Odor from fumes.
1. Dislocated burner
2. Damaged burner
3. Dirty flue tube
L. FUSES
1. Refrigerator control system
2. Refrigerator AC Supply
3. 3-Way only, in-line fuse for 12 volt DC heater
See page 12, part FUSES.
NOTE: AVOID SPRAYING WATER THROUGH THE
REFRIGERATOR VENTS WHILE WASHING YOUR RV.
All the above instructions are to be followed closely. The
refrigerator is quality-guaranteed. However, we are not
responsible for any failures caused by improper adjust-
ments and unfavorable installation conditions. Contact
service point or distributor service dept. for assistance.
CHANGING DOOR HINGES FROM ONE
SIDE TO THE OTHER
The refrigerator is equipped with convertible doors. To
change the door swing, consult the parts manual for the
Conversion Kit Number. For further information, please
contact Dometic Corporation listed on the front page.
INSTRUCTIONS FOR MOUNTING
THE DOOR PANEL
The refrigerator is normally delivered without door panels.
Before starting the mounting work, check that the panel
dimensions are in compliance with those given in the
table and the instructions are read thoroughly.
When mounting the panel, proceed as follows:
See figure page 15.
A. Open the door 90 degrees.
On new refrigerators, the decoration strips are
taped inside the door; if installed on the door,
remove the door decoration strip (2) by removing
its three screws (1).
B. Insert the vertical edges into the grooves of the
door frame (3).
C. Push the panel downward so that the lower hori-
zontal edge of the panel (4) is fitted into the bottom
grove (5).
D. Put the decoration strip across the door so that the
gap is covered. Secure the decoration strip with the
three screws removed in Step A (1).
SPARE PARTS
The following list is a list of commonly used parts, which
should be available, if required, from your Dometic Ser-
vice Center.
A = RM 2662; B = RM 2663;
C = RM 2862.
Part No. Description
17 37 68-03/7 A B C Heater, 325W, 120V
17 37 57-08/9 - B - Heater, 215W, 12V
200 74 19-21/7 A B C Jet, No. 58
293 06 97-07/9 A B C Burner, with conductor
293 11 32-02/7 A B C Spark ignition device
293 20 52-01/8 A B C Thermocouple
293 20 93-03/8 A B C Handle (black)
293 21 06-01/2 A B C Lamp cover
293 25 75-01/8 A B C Door shelf, lower
293 25 76-01/6 A B - Door shelf, 2 pieces
293 25 76-01/6 - - C Door shelf, 3 pieces
293 26 21-01/0 A B C Vegetable box
293 26 67-03/9 A B - Baffle
293 26 67-04/7 - - C Baffle
293 27 81-01/2 A B C Electrode
293 27 50-11/6 A B C Door reversing kit,
right-left (black)
293 27 50-12/4 A B C Door reversing kit,
left-right (black)
293 27 50-15/7 A - C Door reversing kit,
right-left (silver)
293 27 50-16/5 A - C Door reversing kit,
left-right (silver)
Contact an authorized service center for
parts and repairs as needed.
PANEL DIMENSIONS
MAX. THICKNESS 5/32" (4 mm)
REFR. MODELS HEIGHT WIDTH
TYPE MAX. MIN. MAX. MIN.
RM 2662 RM 2663
upper mm 403 401 527 524
inch 15-27/32 15-25/32 20-3/4 20-5/8
lower mm 827 825 527 524
inch 32-9/16 32-1/2 20-3/4 20-5/8
RM 2862
upper mm 403 401 527 524
inch 15-27/32 15-25/32 20-3/4 20-5/8
lower mm 983 981 527 524
inch 38-11/16 38-5/8 20-3/4 20-5/8