User manual
20
Installing the Ventilation and Fume System
6.4
1 = Exhaust Pipe
2 = Fresh Air Hose
3 = Sealing Ring
4 = Bottom Part (Flue)
5 = Top Part (Flue)
MOUNTED ON THE
APPLIANCE :
7 = Connection Fume
Extraction
8 = Water Separator /
Fresh Air Inlet
1.
2.
3.
4.
5.
Connections
7.
8.
Bolt (to secure the pipe)
Exhaust Pipe Ü silver / metal ; length : 500 mm supplied; 1500 mm available on special
request ; (approval min. 200 mm , max. 1500 mm)
The flared flange is fixed with a gasket and an union nut at the refrigerator and the
other side is fixed with a gasket and a bolt at the flue outlet.
Ensure that there is enough distance to flamable parts (min. 50mm).
(the exhaust pipe gets hot in use)
Fresh Air Hose Ü black / plastic ; length : 500 mm supplied; 1500 mm available on special
request; (approval min. 200 mm , max. 1500 mm)
The kit contents the following parts ( without the fixing screws ):
Pipe and Hose mounted
{
Union Nut
Gaskets
Hose Clamps
6
1.
2.
6.
6.
3.
92 mm
65 mm
6.
7.
8.