MANUAL CARAVAN RA/RM-2D GA S 0402 RM 7701 Deutsch Seite 3 English page Français Svenska 822 70 99-03 Español pagina 37 12 Suomi sivu page 20 Italiano pagina 54 sida 29 46
OPERATING AND INSTALLATION INSTRUCTIONS FOR DOMETIC REFRIGERATORS INTRODUCTION CONTENTS We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it, but first a few well-meant words of advice: OPERATING INSTRUCTIONS ............................ 13 CONTROLS .................................................... 13 It is important to read through these instructions carefully before using the refrigerator. STARTING THE REFRIGERATOR .................
6. Hold the button (C) an additional 10-15 seconds to activate the flame failure device, then release it. If the lamp start flashing again, repeat step 4-6. To terminate gas operation, turn the knob (A) to “OFF” position. OPERATING INSTRUCTIONS CONTROLS 230-240 V operation A B C D Fig. 1 The refrigerator can be run on 230-240 V, 12 V or LP gas. Changing between these modes of operation is carried out by means of the control buttons positioned as shown in fig. 1.
DEFROSTING Frost will gradually accumulate on the refrigerating surfaces. It must not be allowed to grow too thick as it acts as an insulator and adversely affects refrigerator performance. Check the formation of frost regularly every week and when it gets about 3 mm thick, defrost the refrigerator. To defrost the refrigerator, turn it off and remove the ice trays and the food item, leave the cabinet and freezer doors open.
4. Gas pressure is incorrect - please check the pressure regulator on the gas container. 5. The ambient temperature is too high. 6. Too much food is loaded at one time. 7. The door is not properly closed or the magnetic sealing strip is defective. If the refrigerator still does not work properly, call a service technician. WARNING! The sealed cooling system must not be opened, since it contains corroding chemicals under high pressure.
It is not a good practice to install the refrigerator so that the vent openings are covered by the vehicle’s entrance door when this is set open. This would reduce the ventilation airflow to the cooling unit and reduce refrigeration performance. VENTILATION OF THE UNIT The enclosure Side ventilation. The refrigerator must be installed in a substantial enclosure and must be level, the dimensions are shown in TECHNICAL DATA.
VENTILATION OF THE UNIT Sealing gasket e.g. of V-type 60 This piece is already on the refrigerator Condenser Cut out opening for the side vent L500 is 451 x 341 mm. Condenser min. ventilation height min. ventilation height Cut out opening for the side vent L500 is 451 x 341 mm. Cut out opening for the side vent L500 is 451 x 341 mm. 385 min. 510 40 Batten attached to the floor FIG. 3a Cut out opening for the roof vent R500 is 507 x 87 mm. min. 510 FIG. 3b Sealing gasket e.g.
LP GAS CONNECTION The refrigerator is designed for operation on LP gas, the pressure of which must be 30 mbar for Propane. Check that this is stated on the data plate. The refrigerator is not designed for operation on town gas or natural gas. CAUTION! Check that the gas supplied to the refrigerator is at the correct pressure. See the reducing valve on the LP gas container. The gas installation should only be carried out by a person experienced in gas fitting.
RM 7701 Overall dimensions, refrigerator Height (incl. controls) ........................ 1595 mm Width ................................................ 525 mm Depth (incl. cooling unit) with door ........................................... 545 mm without door ...................................... 495 mm Recess dimensions Height ............................................... 1598 mm Width ................................................. 530 mm Depth ................................................
Positionierung von Regale Positioning of shelves Installation des clayettes Omplacering av hyllor 64 Hyllyjen säätö Posizionamento dei ripiani MO-FO 0320