User manual
24
B
C
A
Sealing resistant to high
temperature(200°C)
( e.g. HydroSil 3501)
Stop ledges
Ventilation grilles
Ventilation grilles
Truma-flue outlet
AK3
Lip seals
Do NOT use any easily inflammable materials (in particular silicone sealing
agent or similar) for sealing! The device manufacturer's product liability
and guarantee shall lapse if such materials are used.
Draught-free installation
Refrigerators in motorhomes, caravans or other vehicles must be installed in a
draftproof manner (EN 1949). This means that the combustion air for the burner is
not taken from the living area and that exhaust fumes are prevented
from entering the living area .
In no case, use sealing material or foam, in order to build in the fridge
draught-free.
This installation option facilitates the removal and installation of the appliance for
servicing.
In the recess intended for the refrigerator's installation, stop bars (B) are attached
below and on each side. These stop bars are subsequently provided with lip seals (C).
The upper seal of this recess (A) must be manufactured of a material capable of with-
standing high temperatures.
8.3
Proposal: Use of Profile Lip Seals
Ensure that the refrigerator is installed level in the recess.
L300
or
L
500
L300
or
L
500
B