28
8.5
For installing the Truma-roof flue outlet a round cut-out with a diameter of 65mm is fixed onto the
vehicle roof. The roof flue outlet gets screwed in the roof cut-out.
Truma - roof flue outlet AK3
Truma roof flue outlet
AK3
Truma part number :
30700-03
Truma pipe
Truma part number :
39450-00
The flexible high-grade steel
flue outlet tube is pushed into
the roof flue outlet as well as
put unto the mouth of the gas
exit and fixed with a worm
clamp or the screws, supplied
by Truma.
The gas routing has to be
mounted constantly ascen-
ding.
The minimal installation height of the flue outlet tube, between the upper edge of the appliance
and the gas exit at the flue outlet may not be below 250mm. Maximally 1500mm are possible.
A distance of at least 50mm to surrounding walls and furniture has to be kept.
3. Insert the ventilation
grilles.
5. Insert winter cover.
2. Insert the frame and
screw into position.
4. Lock the ventilation grilles.
1. Seal the mounting frame, making it waterproof.
To install the ventilation grilles, cut two rectangles (L300 = width 490mm, height 249mm,
L500 = width 451mm, heigth 341mm)
n the outer wall of the vehicle (for position of the
cuts, see point 8.4).
L300 or L 500
Installing the ventilation system
Truma- roof flue outlet
AK3
L 300
L 300