Gas installation
The rules in point 6.1 must be adhered to.
When running on gas, these appliances are intended exclusively to use
liquid gas (propane/butane) - under no circumstances should town gas or
natural gas be used (EN 27418).
A fixed, pre-set pressure regulator complying with EN 12864 must be
connected to the liquid gas cylinder.
The pressure regulator must concur with the operating pressure specified
on the data plate of the appliance. The operating pressure corresponds to
the standard pressure of the country of specification (EN 1949, EN 732).
Only one connection pressure is permissible for any one vehicle. A plate
showing the permanent, clearly legible notice must be displayed in full view
at the point where the gas cylinder is installed.
The gas connection to the appliance must be installed securely and at
zero potential using tube connectors and must be securely connected to the
vehicle (a hose connection is not permissible) (EN 1949).
29
8.7
8.6
Securing the refrigerator
In the sidewalls of the refrigerator, there are four plastic sleeves with screws for secu-
ring the refrigerator. The sidewalls or rails attached for
securing the refrigerator must be designed in such a way
that the screws will remain firmly in place even when
under increased load (while the vehicle is moving).
Always insert screws through the sleeves provided;
otherwise, structural parts embedded in the foam,
such as cables, etc., may be damaged.
Once the refrigerator is in its final position, secure the
screws into the wall of the recess.
The screws must penetrate
through the sheet metal casing
of the refrigerator.
For installing the Dometic wall flue outlet, provide a round cut-out with a diameter of 65 mm in
the vehicle wall. The wall flue outlet gets screwed in this cut-out.
Dometic wall flue outlet CC 05
B
The flexible high-grade steel flue outlet tube is
pushed into the wall flue outlet as well as put
unto the mouth of the gas exit (B) and fixed
with a worm clamp. The gas routing has to
be mounted constantly ascending. The
minimal installation height of the flue outlet
tube, between the upper edge of the appliance
and the gas exit at the flue outlet (middle) may
not be below 140 mm. A maximum tube length
of 500 mm is possible. A distance of at least 50
mm to surrounding walls and furniture has to
be kept.
Dometic wall flue out-
let CC 05
Dometic part number :
44880
Truma pipe
Truma part number :
39450-00