Gas operation
The refrigerator should only be operated using liquid gas
(propane, butane). Do not use town gas or natural gas.
If the refrigerator is operated during travel using gas, the precautions
stipulated by the legislation in the respective country must be taken (in
conformity with the European standard EN 732).
Operating the refrigerator with gas is not permitted during travel in
France and Australia.
As a basic rule, operation using gas is prohibited in petrol stations.
1. Open the valve of the gas cylinder.
2. Open the shut-off valve to the gas supply.
The ignition process is activated automatically, accompanied by a ticking sound
approx. 30 sec. Upon successful ignition, the display LED “C” “Gas” lights yellow.
The refrigerator is in function. Use rotary switch “B” to regulate the temperature in the
main refrigerator compartment.
- Repeat the entire process if the flame has gone out.
- Use rotary switch (B) to regulate the temperature in the main refrigerator compart-
ment.
All refrigerators, whether manual or automatic ignition, are equipped with
automatic flame protection, which automatically cuts off the supply of gas
approximately 30 seconds after the flame goes out.
When using for the first time, and after changing the gas cylinder, the gas
pipes may contain air. By means of brief operation of the refrigerator and
any other gas appliances (e.g. cookers), air is removed from the gas
pipes. The gas will then ignite without delay.
A
3. Set energy selector switch “A” to gas.
4. Set rotary switch “B” to “MAX” postion.
C
5.2.2
RMT 7650
RMT 7651 / RMT 7655
3. Set energy selector
switch “A” to gas.
4. Press and hold
rotary switch “B”.
5. Activate ignition
by pressing the
button (C) and
keep it depressed.
A
B
C
6. Once the flame has been ignited
and is burning, the needle of the
galvanometer passes over into the
green section.