The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto).
The gas connection may only be carried out by a qualified personnel.
29
Gas-pressure
Following proper installation, a testing for leakage and a flame test must be car-
ried out by *qualified personnel in compliance with EN 1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who are able, by virtue of their training and knowledge,
to vouch for the correct implementation of the leakage test.
BE X
DK X
DE XX
FI X
FR X
GR XX
IE X X
IS X
IT X
LU X X
NL X X
NO X
AT XX
PT X X
SE X
CH X X
ES X
UK X X X
Category I
3P(30)
I
3P(37)
I
3P(50) I
3+ I
3B/P(50)
I
3B/P(30)
mbar 30 37 50 28-37 30-37 50 30
Druckpaar Druckpaar
AATTTTEENNTTIIOONN
20 Nm
max
15 Nm
max
Gas supply
oven
connection
gas supply
Gas burner
Refrigerator
Gas valve
Refrigerator
The refrigerator must be equipped with a gas cock
in the supply line to allow the supply to be disconnected.
Such a cut-out device must be readily accessible to the
user.