9.6 Settings screen (fig. n)
6 Turbo mode:
The coldest setting (level 5) is activated. The outer fan and com-
pressor operate at high speed and the defrost function is disa-
bled.
Turbo mode is active for 12 hours or until the refrigerator reaches
a temperature of –2 °C. After that, the control switches to perfor-
mance mode automatically.
After switching to performance mode, the temperature setting
remains at level 5. At this point the temperature can be set to
levels 1-5 to suit ongoing requirement.
NOTE - inner fan
All cooling modes: the inner fan switches off when the refrigerator
door is opened.
Performance/Silent/Turbo modes: the inner fan cycles on/off with
the compressor.
Eco mode: the inner fan remains on during compressor off cycles.
Symbol Description
Child lock
Beep off
CI-Bus: Not applicable on this model
No. in
fig. m
Description
CI
n
CI
RUC8408X--IO-AU.book Seite 30 Montag, 8. Juli 2019 1:56 13