Specifications

3
Model No. Nominal
Capacity
(BTU HR)
Cooling
Electrical
Rating
120 VAC
60Hz. 1PH
Compressor
Rated Load
Amps
Compressor
Locked
Rotor
Amps
Fan Motor
Rated Load
Amps
Fan Motor
Locked
Rotor
Amps
Refrigerant
R-410A
(Oz.)
Minimum
Wire Size*
12 AWG
Copper
Up to 24'
AC Circuit
Protection
***Installer
Supplied
Minimum
Generator
Size**
1 Unit / 2 Units
457915.30X 13,500 12.4 61.0 2.5 5.8 20.0 20 Amp 3.5 KW / 5.0 KW
457915.70X 13,500 12.4 63.0 2.5 5.8 18.0 20 Amp 3.5 KW / 5.0 KW
459516.30X 15,000 13.4 64.0 2.0 5.6 27.5 20 Amp 3.5 KW / 5.0 KW
459516.70X 15,000 13.3 66.0 2.0 5.6 27.5 20 Amp 3.5 KW / 5.0 KW
SPECIFICATIONS
* For wire length over 24 ft., consult the National Electric Code for proper sizing.
** Dometic, LLC gives GENERAL guidelines for generator requirements. These guidelines come from experiences people
have had in actual applications. When sizing the generator, the total power usage of your recreational vehicle must be
considered. Keep in mind generators lose power at high altitudes and from lack of maintenance.
*** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.