Product Manual

EN
TEC29 EV AUS Installation
13
8.2 Securing the generator
Note on installation location
Make sure that no combustible objects are stored or installed near the air outlet
or the ventilation slots. A distance of at least 50 cm should be kept.
For safety reasons, note the location of existing wiring harnesses, wires and other
components within the installation area, in particular those which are not visible,
when installing the generator (when drilling or screwing etc.).
You can secure the generator with the holders supplied in two ways:
External installation (fig. 5):
External installation has the following benefits: lower space requirement, fast
installation, easy access for maintenance work.
To ensure the generator is attached securely, use the retaining bracket
(fig. 5 1) supplied.
If the air intake opening of the generator is located behind a vehicle wheel,
you need to prevent the wheel from splashing any water into the generator
interior when it rains (e.g. by using a splash guard).
10.5
385
160
99
580
548
480
290
360
1
1
5
TEC29EV-IO-AUS.book Seite 13 Montag, 6. März 2017 8:37 20