Product Manual

EN
Connecting the electrical power to the generator TEC29 EV AUS
20
9 Connecting the electrical power to the
generator
D
A
I
9.1 Important notes on the electrical connection
Only a qualified electrician should connect the generator to the electrical power.
Check that the voltage specification on the type plate is the same as that of the
power supply.
Do not lay the 230 Vw mains cable and the 12 Vg cable together in the same
cable duct.
Do not lay cables which are loose or bent next to electrically conductive material
(metal).
Connect the generator to a power circuit which can supply the necessary current
(see chapter “Technical data” on page 46).
Select the cross-section of the cable as follows:
230 V: 2.5 mm²
Battery connection (length < 6 m): 10 mm²
Battery connection (length > 6 m): 16 mm²
Install a manual main switch which can disconnect all the consumers from the
generator with the exception of the battery.
DANGER! Danger of electrocution
Make sure there is no voltage at electrically operated components
before carrying out work on them!
NOTICE!
Protect the system with an RCD breaker according to AS3001
regulation.
NOTE
Observe the applicable guidelines in the country of the consumer.