TEC29 EV AUS Operating the generator
29
10 Operating the generator
A
I
10.1 Basic notes on operation
!
Please note the following basic information:
Always check the oil level before use (chapter “Checking the oil level” on
page 34).
Leave the generator running for a few minutes after use without any consumers
before stopping it.
If you are not using your generator for a longer period of time, start it up at least
every 30 days and leave it running for 15 minutes or more.
10.2 Switching the generator to standby or no function
The generator can be switched to standby or no function with the main switch
(fig. 3 1, page 10) in the control panel.
NOTICE!
Do not run the generator over 70 % of the maximum constant output for
the first 50 operating hours (run-in phase).
NOTE
Run the generator at a maximum of approx. 75 % of the maximum
continuous load after the run-in phase.
By doing this you can prolong the service life of the generator and
maximise its efficiency.
CAUTION! Beware of injury
Do not insert your fingers or objects into the air nozzles or the intake
grille.