10.7 Display messages
To reset the digital control panel when a message appears, press the on/off switch.
Display message
Description
Generator behaviour Measures
LOW BATTERY
The battery voltage has fallen
below the minimum value for
starting up (9V).
The generator does not start. Charge the battery.
OIL CHANGE
The number of prescribed oper-
ating hours has been reached for
changing the engine oil.
The generator continues to run. Change the oil (see chapter
“Changing the oil” on page 39),
then restart the generator by
pressing and holding down the
start button.
FUEL LOW
The fuel in the tank is in reserve.
The generator continues to run. Refuel.
OIL ALERT
Insufficient engine oil.
The generator stops. Fill up with oil (see chapter
“Checking the oil level” on
page 34).
GENERATOR ALERT!
General alarm message
Example: The control ring on the
throttle valve of the carburettor
(stepper motor) is faulty.
The generator stops. Check the system by referring to
the troubleshooting table.
If the problem persists, contact
the manufacturer's branch office
in your country (addresses on the
back page).
OVERLOAD!
The consumers generate an
overload at the output.
The inverter switches off, there-
fore no voltage is supplied but
the engine carries on running
until it goes off.
Reduce the connected load and
start the generator again.
SHORT CIRCUIT
The consumers cause a short
circuit at the output.
The inverter switches off, there-
fore no voltage is supplied but
the engine carries on running
until it goes off.
Check the connected
consumers then start the
generator again.
OVER TEMPERATURE
Overheating
The inverter switches off so no
voltage is supplied to cool the
generator, but the engine
wcarries on running.
Leave the engine to cool down
for a few minutes then start the
generator again.