Product Manual

EN
TEC29 EV AUS Operating the generator
35
Take the dipstick (2) out of the filler neck.
Check that the oil level is between the notch (maximum filling level) and the tip of
the dipstick (4).
If not, top up with more oil.
Put the dipstick (2) back into the filler neck (3).
Check that the oil level is not above the maximum level.
Connect the generator to the positive terminal of the supply battery.
Switch the generator to standby with the main switch (1).
Close the generator front door.
10.9 Switching to automatic mode
You can only switch to automatic mode:
if it was configured when the generator was installed (see chapter “Connecting
the autostart wiring” on page 26
if the vehicle is stationary and the ignition is switched off
In automatic mode, the generator switches on automatically and charges the battery
if the voltage of the connected battery is too low.
The generator switches off automatically once the battery has been fully charged.
The generator can also be turned ON/OFF using a remote switch (not provided) as
indicated in fig. h, page 26.
To switch on the automatic mode:
Switch on the automatic mode switch (if available).
Switch the ignition off.
Switch the digital control panel on by pressing the on/off switch.
The display shows:
ENABLE AUTOSTART [HOLD] CONFIRM.
I
NOTE
If
GEN OFF appears on the display instead of ENABLE AUTOSTART [HOLD]
CONFIRM
, the automatic mode is not configured for your generator. If this
is the case, contact the specialist workshop which installed the genera-
tor and have the automatic mode retrofitted.
TEC29EV-IO-AUS.book Seite 35 Montag, 6. März 2017 8:37 20