12.3 Finishing maintenance work
➤ Connect the generator to the positive terminal of the supply battery.
➤ Switch the generator to standby with the main switch (fig. j 1, page 34).
➤ Close the generator front door.
12.4 Changing the oil
!
A
You may use the following oil:
• API SG or SF grade oil for four-stroke engines.
• SAE 10W-30 grade oil (can be used at any temperature).
• Oil with single grade oil viscosity.
Select the appropriate viscosity according to the average temperature on-site.
Change the oil as follows (fig. l):
CAUTION!
Hot oil can cause burns.
NOTICE!
Only dispose of used oil at a specialist recycling station and observe the
local laws for environmental protection.
1
l