The starter turns
but the generator
does not start.
Not enough fuel in the fuel pipe or fuel
tank is empty.
Fill up with petrol.
Spark plug is not receiving any power. Check the electric connections.
Carburettor is not receiving any petrol. Clean the carburettor.
Air intake is blocked. Check the air filter (see chapter
“Servicing the air filter” on
page 40).
Inverter is damaged. Contact an authorised workshop.
Power cable is disconnected or the plug
is removed.
The generator
tends to stall.
Too much oil in the engine. Drain the oil.
Load is over 2.6 kW. Reduce the consumers.
Carburettor is not receiving any petrol. Clean the carburettor.
Air intake is blocked. Check the air filter (see chapter
“Servicing the air filter” on
page 40).
Inverter is damaged. Contact an authorised workshop.
Electromagnet is blocked.
Air filter is dirty.
The generator is
running but does
not supply any volt-
age.
Inverter is damaged. Contact an authorised workshop.
The stepper motor is faulty or the cable is
disconnected.
Electromagnet is blocked.
The throttle valve is blocked.
The generator
starts up very fast
and then the
“GENERATOR
ALERT” message
appears.
Generic alarm If the problem persists, contact an
authorised workshop.
Inverter is damaged. Contact an authorised workshop.
The stepper motor is faulty or the cable is
disconnected.
The generated
voltage is unstable.
Inverter is damaged. Contact an authorised workshop.
The stepper motor is faulty or the cable is
disconnected.
Fault Cause Remedy