User's Manual

9
(非 0)后,保存即可,租赁时间以 1 刻钟为单位,如果设置为 4,表示 4 刻钟(1
小时), 设置范围是 1-30000如果需要禁止,可以在 Enable 处点击并选择 Disable
后,保存即可。
7. The lease time is used to limit the effective working time for the system. The
factory setting is to disable this function, means the system can work for unlimited time.
The status can show whether the lease time function is enabled: enable is to limit the
working time, while disable is not to limit the working time. The available time is the
effective working time that was set for the system, and the elapsed time is the time
that has been used since the setting. If you need to reset the effective working time
for the system, just put a valid number (not 0) at the available time, and click the Save
button to save it. The lease time is based on 1 quarter of the clock, if it is set to 4,
it means 4 quarters (1 hour) ). The setting range is 1-30000. If you need to disable it,
you can click Enable button, and select Disable, then click save button to save it.
8、滤波因数(filter),默认值是 32,设置范围是 0-1023,一般不作修改。
8. The filter is set at 32 by factory, the setting range is 0-1023. Usually it is not
necessary to modify.
9、峰值位置差门限(peak pos gated),默认值是 10,设置范围 0-255
一般不作修。该数值越小,报警的条件越严格,报警约准确。假如存在误报,可以将
该数值调小,反之,如果检测距离不理想,可以尝试将该数值调大。
9. The peak pos gated is set at 10 by factory. The setting range is 0-255, Normally
it is not necessary to modify. When this value is smaller, the alarm possibility is very
low, and the alarm accuracy is very high. If there are false alarms, change to a smaller
value. If the detection is not good, change to a bigger value.
10命中次数hit count默认值是 8设置范围是 1-8如果在一个处理周
期内连续 8 次出现疑似标签信号,则主板将信号判定为真正的标签信号,并发出声光
报警。命中次数与天线识别标签的距离有关系,命中次数越小,报警的概率越高,
之报警的概率越低。在不误报的情况下,可以通过减小命中次数来提高天线识别标签
的距离。
10. The hit count is set at 8 by factory. The setting range is 1-8. In one processing
cycle, if a suspected tag signal appears 8 times, the system will determine this signal is
a true tag, then decide to alarm. The hit count is related to the detection distance.
When the hit count is smaller, the alarm possibility is higher, means the sensitivity is
higher. And vice verse. If there is no false alarm, the hit count can be changed to smaller
to make the detection distance wider.