User manual

13
ENGLISH
PORT DESCRIPTION
LAN/POE RJ45 jack to connect a standard Network cable Cat.5
or better, coming from the Internet Router/PoE-Switch/
PoE-Injector.
Do not power the device simultaneously via
the power supply from the power supply unit
(mains adaptor) and the power supply via PoE.
REL1, REL1 First bi-stable latching relay, max. 1-24 V DC/V AC,
1 Ampere. Security feature: The relay keeps its state
even in the case of loss of power. You can configure the
default state of the relay (open/close) via the DoorBird
App. These ports can be used to connect e.g. an electric
door opener. The device does not supply power to the
connected device. The power supply for the electric door
opener must be installed separately.
REL2, REL2 Second bi-stable latching relay, max. 1-24 V DC/V AC,
1 Ampere. Security feature: The relay keeps its state
even in the case of loss of power. You can configure the
default state of the relay (open/close) via the DoorBird
App. These ports can be used to connect e.g. an electric
door opener. The device does not supply power to the
connected device. The power supply for the electric door
opener must be installed separately.
REL3, REL3 Third bi-stable latching relay, max. 1-24 V DC/V AC,
1 Ampere. Security feature: The relay keeps its state
even in the case of loss of power. You can configure the
default state of the relay (open/close) via the DoorBird
App. These ports can be used to connect e.g. an electric
door opener. The device does not supply power to the
connected device. The power supply for the electric door
opener must be installed separately.
EXT1, EXT1 First Dry-contact (potential-free), max. 0 V DC/V AC,
0 Ampere. These ports can be used to connect e.g. an
external sensor, e.g. door sensor or motion sensor.
You can configure the event to be triggered by these
ports using the DoorBird App.
Please make sure to add no extra voltage on
these ports.
REL1
REL1
REL2
REL2
REL3
REL3
EXT1
EXT1
NOTICE
NOTICE