Owner`s manual

9210-065-H-2-13
10
1.2 Underground Conduit Requirements
Primary/Secondary Interconnection Cable (Dual Operator Application Only)
Sweeps
Concrete Pad
Concrete Pad
3/4 Inch Minimum
Single/
Primary
Operator
Position
Secondary
Operator
Position
SECTION 1 - INSTALLATION
Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with the
instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your installation is
performed in an efficient and professional manner compliant with UL 325 safety and ASTM F2200 construction
standards.
The proper installation of the vehicular slide gate operator is an extremely important and integral part of the
overall access control system. Check all local building ordinances and building codes prior to installing this
operator. Be sure your installation is in compliance with local codes.
1.1 Gate Hardware
DoorKing has a full line of Tandem V-wheels that are ideal for heavy gates and
will ensure safe, reliable and long lasting gate operation. The gate must be
properly installed and roll smoothly in both directions.
Guide Rollers with Protective Covers
Helps to minimize a pinch point on the
gate.
4 Inch6 Inch
The conduit requirements are for a typical slide gate operator installation (the secondary operator is shown for
those applications where a secondary operator may be used). The conduit requirements for your application may
vary from this depending on your specific needs.
Use only sweeps for conduit bends. Do not use 90° elbows as this will make wire pulls very difficult and can cause
damage to wire insulation.
DoorKing recommends using 3/4-inch conduit.
Be sure that all conduits are installed in accordance with local codes.
Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation.
Elbow
NO
Sweep
YES
Control and/or P.A.M.S. Wires (Low Voltage wire insulation)
Loop Lead-In Wires (Low Voltage wire insulation)
AC Input Power (High Voltage wire insulation)