There are 2 speed adjustments that must be adjusted on the 9235. The high speed adjust (Emergency Close) is designed to
close an open gate as quick as possible. All secondary entrapment protection devices and reversing sensors
WILL NOT WORK during the high speed closing operation!
The slow speed adjust is for normal gate operation.
The 9235 models are equipped with a mechanical disc brake. It is automatically controlled by the AC module and needs NO
adjustment. Note: There is a manual release lock on the disc brake that must be unlocked before the gate can be manually
operated (See section 6.3 manual gate operation on page 35 for further information).
9235 Models with AC Module Dual Adjustment and Mechanical Disc Brake
HIGH SPEED
ADJUST
SLOW SPEED
ADJUST
P1
P2
1495-010
Min Max
Speed
Emergency Close Adjustment: Adjust the high speed
from 0 to 6 feet per second. Closing device must be
connected to P2 terminal on 1495 circuit board.
Normal Gate Adjustment: Adjust the slow speed from
0 to 4 feet per second. Opening device must be connected
to 4404 main circuit board (See page 30).
To adjust the speed, rotate each speed control potentiometer clockwise to increase
the gate speed, or counter-clockwise to decrease the gate speed. The digital
readout on the AC module will display EITHER high speed OR slow speed, which
ever open/close device has been activated.
DANGER
Gate WILL NOT stop after the Emergency
Close is activated until gate is closed!
Stand-Alone
Push-Button
Important: Closing device must be far enough from
the gate so that the user is prevented from coming in
contact with the gate while operating the device.
Outdoor or easily accessible closing device should
have a security feature to prevent unauthorized use.
EMERGENCY
CLOSE
10 HP AC Module
AC Module
Dual Adjustment
1
2
5
6
11
13A
13B
13E
25
16
17
U
L1 L2 L3 B- B+
V W PE PE
Mode
EPM
1. 0
SCM series
basic I/O control
1 ft/s
.5 ft/s
0 ft/s 2 ft/s
1.5 ft/s
Min Max
Speed
3.6 AC Module Adjustment
The 9220, 9230, 9235, 9240 and 9245 models are equipped with an AC module that allows you to adjust the speed of the gate
from 0 to 2 feet per second. To adjust the speed, simply rotate the speed control knob clockwise to increase the gate speed, or
counter-clockwise to decrease the gate speed. The digital readout on the AC module will display the gate speed.
3 HP AC Module 5 HP AC Module 10 HP AC Module
1
2
5
6
11
13A
13B
13E
25
16
17
U
L1 L2/N B- B+
V W PE PE
Mode
EPM
1. 6
PE
SCM series
basic I/O control
1
2
5
6
11
12
2
14
13A
13B
13C
15
25
2
30
31
TXA
TXB
U
L1 L2 L3
V
T2
WB-B+
Mode
EPM
T1 T3
2. 0
SCF series
basic I/O control
1 ft/s
.5 ft/s
0 ft/s 2 ft/s
1.5 ft/s
Min Max
Speed
1 ft/s
.5 ft/s
0 ft/s 2 ft/s
1.5 ft/s
Min Max
Speed
2 ft/s
1 ft/s
0 ft/s 4 ft/s
3 ft/s
Min Max
Speed
9235 Only