Owner`s manual

9210-065-H-2-13
27
TIME
DELAY
EXIT
LOOP
LMT
LMT
REVERSE
LOOP
REV SENSE
OPEN
REV SENSE
CLOSE
1
ON
2 3 41
ON
2 3 4 5 6 7 8
NC
NO
P8
P7P6
4404-101
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
TIME
DELAY
EXIT
LOOP
LMT
LMT
REVERSE
LOOP
REV SENSE
OPEN
REV SENSE
CLOSE
1
ON
2 3 41
ON
2 3 4 5 6 7 8
NC
NO
P8
P7P6
4404-101
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
9 V battery operated transmitter mounted on gate.
Wireless Reverse Edge Sample Setup - Single Receiver
Photo Sensor and Wireless Reverse Edge Sample Setup
Closed Gate
Wall
Normally Open
Common
Normally Open
Install Jumper Wire
Common
Normally Open
Normally Open
Common
When either direction reversing edge get obstructed,
the gate will STOP and reverse direction.
Filler Post Note: Install reversing edges on all
the gate support posts or filler post in this area
(e.g. cantilever gate installations, See below).
Wireless Note: Refer to the
instruction sheet that comes
with the receiver/transmitter
for more specific wiring and
mounting instructions.
Closing-
Direction
Reversing
Edge
Closing-
Direction
Reversing
Edge
Opening-Direction
Reversing Edge
Opening-Direction Reversing Edge (If filler post is used).
9 V battery operated transmitter mounted on gate.
Filler Post
(If necessary)
Edge
Transmitter
Edge
Transmitter
To #3 24 Volt - Power is limited to 250 mamps.
To #3 24 Volt - Power is limited to 250 mamps.
Coax Antenna Kit
P/N 1514-073
To #1 Com
To #1 Com
Antenna mounted
outside operator cover.
24 VAC Receiver
Place receiver in operator.
1
2
3
4
5
6
6-Pin
UL 325
Terminal
Wiring
6-Pin UL 325
Terminal Wiring
Normally Open
Normally Open
Common
Common
Opening-Direction Photo Beam
Normally Open
Common
Wireless Note: Refer to the instruction sheet that comes with the receiver/transmitter for more specific wiring and mounting instructions.
20-Pin
Main
Terminal
20-Pin
Main
Terminal
Photo Sensor Power Note: Photo sensors can be powered by the built-in convenience
outlets located on the operator (See page 25).
Install Opening-Direction
reverse edges on the gate
support post(s) in this area.
12
3456
Cantilever Gate
Coax Antenna Kit
P/N 1514-073
Antenna mounted
outside operator
cover.
OPEN Entrapment Sensor
CLOSE Entrapment Sensor
OPEN Contact Sensor
CLOSE Contact Sensor
Low Voltage Common
Low Voltage Common
OPEN Entrapment Sensor
CLOSE Entrapment Sensor
OPEN Contact Sensor
CLOSE Contact Sensor
Low Voltage Common
Low Voltage Common
24 VAC Receiver
Place receiver in operator.
When a reversing edge gets obstructed, the
gate will STOP and reverse direction. When
a photo beam gets obstructed the gate will
STOP, then continue in the same direction
after obstructed photo beam has been
cleared until the gate cycle is complete.