Specifications

Anti-Grounding Plate
TIME
DELAY
EXIT
LOOP
LMT
REVERSE
LOOP
REV SENSE
OPEN
REV SENSE
CLOSE
1
ON
2 3 41
ON
2 3 4 5 6 7 8
NC
NO
P8
P7P6
4404-010
20 19 18 17 16 15 14 13 12 11 10 987654321
94109410
1
2
5
6
11
13A
13B
13E
25
16
17
U
L1 L2/N B- B+
VWPE PE
Mode
EPM
Speed
Controller
1.0
PE
SCM series
basic I/O control
115 VAC Convenience Outlets
DO NOT
power up and
cycle the operator until
the “DIP-Switches” and
the “Limit Switches”
have been adjusted.
Damage could occur to
the gate and operator.
T
T
T
T
T
T
T
T
T
Opening direction
using OFF setting.
Opening direction
using ON setting.
EXIT
LOOP
LMT
REVERSE
LOOP
REV SENSE
CLOSE
P8
P7
P6
4404-010
1
2
4
3
1
2
4
3
1
2
4
3
Electronic Box
Power safety and opening devices
that require 115 VAC power.
Two 115 VAC Convenience Outlets
Clear Plastic Electronic Box Cover
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Model 9200 is intended for installation only on sliding gates used for vehicles.
Pedestrians must be supplied with a separate access opening. For safety and installation instructions,
please refer to the Installation/Owner’s manual.
Copyright 2013 DoorKing, Inc. All rights reserved.
9210-066-E-2-13
Plug-In Loop Detectors
Not included - Refer to the Installation/Owner’s manual AND
Loop Information Manual (available from www.dkaccess.com)
for more information on loops and plug-in loop detectors.
Important Note: DoorKing highly recommends that loops and
loop detectors are installed with this slide gate operator. A loop
detection system will preventing the gate from automatically
opening or closing on a vehicle when it is in the gate’s path.
High Voltage Connection
Tip: It is recommended that a surge suppressor be installed on the high voltage
power lines.
GATE OPERATOR MUST BE PROPERLY GROUNDED!!
DIP-Switches
Limit Switches
1. Opening Direction
2. ON
3. ON
4. OFF
5. OFF
6. OFF
7. OFF
8. OFF
1. OFF
2. OFF
3. OFF
4. OFF
Auto-Close Timer
Chassis
Ground
DANGER
HIGH VOLTAGE!
1
ON
2 3 4 5 6 7 8 1
ON
2 3 4
SW 1 and 2 are Upside-Down on Circuit Board.
123
TIME
DELAY
A
B
D
C
C C
B
D
1 ft/s
.5 ft/s
0 ft/s 2 ft/s
1.5 ft/s
Limit LEDs
Plug-In Loop
Detector
Plug-In Loop
Detector
MinMax
Speed
Push
Push
Lock-Plate
Limit Nut
Limit Nut
Slow-Down Limit
Slow-Down Limit
1A
2A
Partial Open
Not Used
1
2
2A
1A
Adjust 1 to 23 sec.
See reverse side
See reverse side to wire main terminal.
1 Limit
Switch
2 Limit
Switch
Check polarity of Three Phase:
Position the gate half way open.
Give open command and while
gate is opening, activate the
appropriate limit switch with your
finger. Gate should STOP. If it does
not, activate the other limit switch.
If this STOPS the gate, AC power
wires must be changed (Reverse
the connection of any 2 wires and
re-check limits).
Partial Open Adjustment Rail
208/230 VAC
THREE Phase
Chassis
Ground
High
Voltage
AC Input
Wire
Hot
115 VAC Output
HotHot
208/230 VAC
SINGLE Phase
Chassis
Ground
High
Voltage
AC Input
Wire
Hot
115 VAC Output
Hot
Use only two legs
of the incoming
3-phase power.
Chassis
Ground
High
Voltage
AC Input
Wire
Hot
115 VAC Output
Neu
115 VAC
SINGLE Phase
White - Neutral
Black - 115 VAC Hot
Green - Chassis
Ground
SW 1SW 2
AA
A
Idler
Wheels
Operator Housing
14”14” 14” 14”
Gate
Operator MUST be parallel to gate!
Chain brackets MUST
align with idler
wheels so chain
stays parallel to gate!
Chain brackets MUST be mounted so
the chain remains the same height as
it is on the idler wheels!
Chain
Bracket
Chain
Bracket
Chain
Bracket
Idler Wheels
Operator Base Plate
Chain
Configuration
Concrete Pad
Concrete Pad
4” Min. Above Ground
Remove the limit assembly guard.
Remove the 3 locknuts inside the electronic box
to swing box open.
WARNING
MOVING GATE CAN CAUSE
Operate gate only when gate area is in sight
and free of people and obstructions.
D
o not allow children to play in gate area
or operate gat
e.
Do not stand in gate pat
h
or walk through
path while gate is moving.
Read owner’s manual and safety instructions.
SERIOUS INJURY OR DEATH
CLASS
CERTIFIED TO
CAN/CSA C22.2 NO. 247
CONFORMS TO
ANSI/UL-325
VEHICULAR GATE OPERATOR
HP
5
3382
MODEL
SERIAL
VOLTS
PHASE
AMPS 60 Hz
MAX GATE LOAD
DoorKing, Inc., Inglewood, CA
Limit Assembly Guard
Electronic Box
Tip: Trace the base plate of the operator on a piece
of masonite (Not provided) and make a template to
help locate where the conduit runs will be positioned
in the concrete pad.
Pad depth is determined by soil
conditions and local building codes.
Minimum depth is 18 inches.
Reinforced concrete recommended.
Gain Access Inside Operator
Top
View
Side
View
3/4”conduit
with sweeps
recommended.
Conduit
Area
Conduit
Area
Conduit
Area
1
2
3
Masonite Template
Not Provided
Conduit
Cutout
Conduit
Cutout
Conduit
Cutout
Concrete pad MUST be level!
1/2
Attach operator to
concrete pad with
twelve (12) 1/2” x 3”
sleeve anchors (not
supplied) after
concrete pad has been
poured and has cured.
18”
20”
Wire
Mesh
23”
28”
1”
1”
4”
4”
Manual
crank in
stored
position.
Manual Crank
Access Panel
Conduit suggestions:
High voltage conduit
Low voltage access control device conduit
Reverse loop conduit
Automatic exit loop conduit
Idler wheels
are factory set
in the correct
position.
Remove the chain
knock-outs from
operator housing.
Caution:
Never
attempt to
manually
operate the
9200 until
you have
verified that
power has
been shut-off.
Chain Knock-out
Connect
Chain
to Gate
Chain nut
and chain bolt
should not protrude
past gate frame. The chain
should sag no more than
one (1) inch per 10 feet of
travel. Do not over tighten
the chain.
Chain
Nut
Chain Bolt
Option 2
Master Link
Option 1
Gate
Frame
QUICKSTART “BASIC” GUIDELINES FOR MODEL 9200 “FULL OPEN”: MOUNTED DIRECTLY ON A CONCRETE PAD
Speed Control Knob
On all models but 9210.
All 9200 Models: DoorKing highly
recommends using the pedestal mounting stand
for gates heavier than 2000 lbs. for a more secure
attachment to a larger and heavier concrete pad.
CAUTION
High Voltage AC input power MUST MATCH
the operator specifications or DAMAGE will
occur and VOID the warranty!
VERIFY Input AC power MATCHES your
specific operator power BEFORE wiring!
With power OFF, push and hold the
lock plate down where shown to
adjust the Open and Close limit nuts.
After adjusting the limit-nuts, be sure
that the lock-plate is engaged in the
slots on the limit-nuts to prevent them
from rotating.
The slow-down limits on all models
but the 9210 will move up or down
3/4 inch. DO NOT remove the
slow-down limit assembly from the
3/4 inch slot and re-attach it in the
longer slot on the partial open
adjustment rail to gain further
adjustment. This will cause mechani-
cal damage to the switch assembly
when the operator is activated.
Turn power ON and activate the gate
operator. Re-adjust the limit nuts as
necessary for full-open and full-close
gate travel. After you are satisfied with
the gate limit settings, the speed
control knob can then be adjusted on
all models but the 9210 to personal
preference.