Owner`s manual

20
3.1.2
In this layout, the Model 2000 has been positioned close to the AC power distribution panel rather
than being installed at the gate site. AC power is routed into the Model 2000 from the distribution
panel and is then distributed to the various devices to be powered. It is critical that the AC wires
that provide power to the Model 2000 be of a sufficient size to handle the power required by
ALL the operators powered from the Model 2000. This may require a fairly large wire size, such as
8, 6 or 4 AWG depending on the number of operators and wire run distances involved. It is best to
have a licensed electrician determine the proper wire size required.
Power is distributed from the Model 2000 to each of the gate operators. Refer to the gate operator
installation instructions or consult a licensed electrician to determine the proper wire size required to
supply adequate power to the gate operators.