Owner`s manual

9510-065-L-3-13
11
56”
36”
4”
10.5”
24” depth up to 8,000 lb. gate.
36” depth up to 25,000 lb. gate.
4”
10.5”12”12”
12” 12” 12”
12”
Wire Mesh
1.4 Concrete Pad Description
• Use 1/2” re-bar. 4 per concrete post.
• Wire mesh is highly recommended.
• 4 underground conduits recommended:
- High voltage AC power
- Low voltage controls
- Reverse loops
- Automatic exit loop.
Above ground conduits can be routed after the operator has
been installed using junction boxes if desired.
• Position operator approximately 4 inches away from the
gate frame and secure to concrete with sleeve anchors.
See page 13 for further information.
Top View
End View
Front View
Back Anchor Foot
Front Anchor Foot
Front
Anchor
Foot
Back
Anchor
Foot
Concrete Pad
Conduit
Area
Above Ground
3/4”
Conduit
3/4”
Conduit
Re-bar
Sleeve
Anchors
Note: Minimum suggested pad size.
The pad size will vary for each installa-
tion. It is important to have enough
concrete mass in the ground to
securely anchor the operator. This
prevents the pad from shifting in the
ground when cycling very heavy gates.
Be sure the top of the concrete pad is level and a minimum of four (4)
inches above ground level. See the next page for typical gate types.
We suggest that you contact the local building department to
determine the required depth of the pad since soil
conditions and code requirements vary from city
to city.
Front View
End View
Above Ground
Top View
Top MUST
Be Level!
Gate Frame
3/4”
Conduit
(Sweeps)
Re-bar
Re-bar
V-rail v-wheel
gate type shown.