Owner`s manual

9510-065-L-3-13
17
TIME
DELAY
EXIT
LOOP
LMT
LMT
REVERSE
LOOP
REV SENSE
OPEN
REV SENSE
CLOSE
1
ON
2 3 4 1
ON
2 3 4 5 6 7 8
NC
NO
P8
P7 P6
4404-010
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Mechanical
Disc Brake
Plug P8
3.1 4404 Circuit Board Description and Adjustments
SECTION 3 - ADJUSTMENTS
The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is
complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then
turned back on for the new setting to take effect.
Auto-close timer (when
turned on) SW 1, switch 2.
Dry relay contacts
(terminals 11-12) can be
set for Normally Open
(NO) or Normally Closed
(NC) operation by placing
the relay shorting bar on the
N.O. or N.C. pins respectively.
SW 1, switches 4 and 5 must
be set to control relay. See
next 2 pages for descriptions.
Auto-Close Timer
AC Module
Adjustments
Dual Channel Loop DetectorSingle Channel Loop Detector
Dry Relay Contact
Set the DIP-switches on the
circuit board to the desired
setting. See switch setting
descriptions on next 2 pages.
DIP-Switches
LEDs Indicates that low voltage power is applied to the circuit board. Input LEDs should be OFF and will only
illuminate when the input is activated. Limit LEDs will be on when the respective limit switch is activated.
Adjust reversing
sensitivity for
open and close
directions.
Full counter
clockwise for
minimum
sensitivity, full
clockwise for
maximum
sensitivity.
See page 21.
Inherent
Reverse
Sensors
Motor
Plug P6
Limit Switch Plug P2
Self-test (when turned on)
SW 2, switch 1.
CAUTION
Do not run self-test with the
operator connected to the gate.
The drive chain must be
disconnected before running the
self-test. This feature is designed
for bench testing ONLY.
Self-Test
UL 325 Terminal
Power LED
LMT
Limit LEDs
Input LEDs
Input LED
Input LEDs
9410
9409
1 23
Adjust from 1 second
(full counter-clockwise) to
approximately 23 seconds
(full clockwise).
NC
NO
Min Max
CLOSE
Sensitivity
OPEN
1 ft/s
.5 ft/s
0 ft/s
2 ft/s
1.5 ft/s
2 ft/s
1 ft/s
0 ft/s
4 ft/s
3 ft/s
Min Max
Speed
See page 22 for
description.
See page 26 for
loop information.
Exit
Loop
Port
Reverse Loop Port
1
ON
2 3 4 5 6 7 8
SW 1 is Upside-Down on Board
1
ON
2 3 4
SW 2 is Upside-Down on Board
1
ON
2 3 4
SW 2 is Upside-Down on Board
1
ON
2 3 4 5 6 7 8
SW 1 is Upside-Down on Board
1
ON
2 3 4 5 6 7 8
SW 1 is Upside-Down on Board