3.6 AC Module Adjustment
9500s are equipped with an AC module that allows you to adjust the speed of the gate from 0 to 2 ft/ sec or 0 to 4 ft/sec on the
high speed models. To adjust the speed, simply rotate the speed control knob clockwise to increase the gate speed, or counter-
clockwise to decrease the gate speed. The digital readout on the AC module will display the gate speed.
The 9555/9556 10:1 gear reducer is equipped with a disc brake. It is automatically controlled by the AC module and needs NO
adjustment. There is a manual release lock on the disc brake that must be unlocked before the gate can be manually operated
(See section 6.3 manual release on page 33 for further information).
9555/9556 Mechanical Disc Brake
10 HP AC Module
Mechanical
Disc Brake
Manual Release
NO adjustment is needed for the disc brake.
1
2
5
6
11
12
2
14
13A
13B
13C
15
25
2
30
31
TXA
TXB
U
L1 L2 L3
V
T2
WB-B+
Mode
EPM
T1 T3
1. 0
SCF series
basic I/O control
Min Max
Speed
1 ft/s
.5 ft/s
0 ft/s 2 ft/s
1.5 ft/s
15 HP AC Module
1
2
5
6
11
12
2
14
13A
13B
13C
15
25
2
30
31
TXA
TXB
U
L1 L2 L3
V
T2
WB-B+
Mode
EPM
T1 T3
3. 0
SCF series
basic I/O control
Min Max
Speed
2 ft/s
1 ft/s
0 ft/s 4 ft/s
3 ft/s