Owner`s manual

9510-065-L-3-13
26
TIME
DELAY
EXIT
LOOP
LMT
LMT
REVERSE
LOOP
REV SENSE
OPEN
REV SENSE
CLOSE
1
ON
2 3 41
ON
2 3 4 5 6 7 8
NC
NO
P8
P7P6
4404-010
20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
4 Ft. Min. to avoid reverse
loop interference.
94109410
Single Channel Single Channel
A
B
Automatic Exit Loop
Automatically opens the gate for exiting
vehicles without having to use a transmitter or
keypad. The exit loop can be placed a minimum
of 4 feet away from the reverse loop or far
enough away from the gate so the gate has
started opening or even completely opened by
the time you drive up to it (Free exit).
B
LOOP 1
PVC Conduit
Exit loop lead-in
wires are twisted
approx. 6 twists
per foot.
Exit Loop Port
Reverse Loop Port
W
A
R
N
I
N
G
M
O
VI
N
G
G
A
T
E
C
A
N
C
A
U
S
E
O
per
a
t
e
g
a
t
e
o
n
l
y
w
h
e
n
g
a
t
e
ar
ea
is
i
n
s
i
g
h
t
a
n
d
f
r
e
e
o
f
p
e
op
l
e
a
n
d
o
b
s
t
r
u
c
ti
o
n
s
.
D
o
n
o
t
allo
w
c
h
i
l
d
r
en
t
o
p
l
a
y
i
n
g
a
te
a
r
e
a
o
r
op
e
r
a
t
e
g
a
te
.
D
o
n
o
t
s
t
an
d
i
n
gat
e
p
a
t
h
o
r
w
a
l
k
t
h
r
o
u
g
h
p
a
t
h
w
h
i
l
e
ga
te
i
s
m
o
v
i
n
g.
R
e
a
d
o
w
n
e
r
’
s
m
a
n
u
a
l
a
n
d
s
a
f
e
t
y
i
n
st
r
u
c
t
i
o
ns
.
SE
R
I
O
U
S
I
N
J
U
R
Y
O
R
D
E
A
T
H
Reverse
Reverse
Automatic Exit
4 Ft. Min. to avoid gate
movement interference.
4 Ft. Min. to avoid gate
movement interference.
Single Channel Single Channel
4.3 Loop Detector Wiring
Loop Lead In Wire
Loop Lead In Wires
DoorKing
Plug-in
Loop Detectors
Reverse Loops
Reverse loops are placed on each side of the gate to
prevent the gate from closing on a vehicle in the gate’s
path. They will stop or reverse the cycling of the gate
while a vehicle is in or near the gate’s pathway.
To help protect the operator from accidentally closing on vehicles in the gate’s path, DoorKing highly recommends that loops
and loop detectors be installed. Loops are laid underneath, cut into asphalt or concrete driveways or buried beneath gravel and
earth driveways. A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator
preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path. DoorKing recommends that
a licensed installer perform this work.
Reverse loop
lead-in wires are
twisted approx.
6 twists per foot
and are wired in
series.
A
LOOP 1
DoorKing offers a free “Loop and Loop-Detectors
Information Manual” PDF located at Doorking’s
web site for more information. www.dkaccess.com
PVC Conduit
Note: SW 1, switch 7
must
be set for the reverse loops.
See page 19 for more
information about SW 1,
switch 7 ON/OFF options.
1
ON
2 3 4 5 6 7 8
SW 1 is Upside-Down on Board
Note: Loop detector
wiring is shown for
DoorKing plug-in
loop detector P/N
9410-010 (Single
Channel). If other
loop detectors are
used, refer to the
installation
instructions
supplied with those
detectors for wiring
and separate power
instructions.
1
ON
2 3 4 5 6 7 8
SW 1 is Upside-Down on Board
1
ON
2 3 4 5 6 7 8
SW 1 is Upside-Down on Board
Note: The plug-in exit loop detector can be
wired to partially open the gate if SW 1,
switch 3 is turned OFF. A jumper wire must
be connected from terminal #4 to terminal
#5 (See next page for more information).
Exit Loop Partial Open
SW 1, switch 3
must be
ON to
FULLY open gate
(Normal function).