Operation and maintenance manual
DX140R/DX140LCROperating Controls
2-12
8. Light Switch
This switch is used to turn "ON" the lights.
O. In this position, all lights are "OFF".
I. In this position, all illumination lights of the instrument
pan
el and the control switches are turned "ON".
II. In this position, all illumination lights and work
lights
are turned "ON".
9. Breaker/Boost/Shear Selector Switch
This switch is used to either select the breaker, power
boost, or shear.
O. In this position, a hydraulic pressure rise will be
a
ctivated when pressing the button on the right-hand
work lever (joystick).
I. In this position, shear is activated.
II. In this position, breaker is activated.
Figure 15
O
I
II
FG000024
CAUTION
AVOID INJURY
Do not leave instrument panel or work lights "ON"
when t
he engine is not running. Leaving lights "ON"
with the engine stopped will discharge batteries.
Figure 16
POWER UP
FG000025
O
I
II
CAUTION
AVOID INJURY
Before using any attachment in a work application, be
sure
to check its functional control. Make sure that
desired movement or action is being activated by the
control. e.g. opening/closing, CW/CCW, crowd/dump,
etc.