Operation and maintenance manual
Operation
3-9
DX140R/DX140LCR
Hydraulic System Warm-up
The correct operating temperature of the hydraulic oil is 50° -
80°C (120° - 175°F). Make sure to follow the procedures listed
here for hydraulic fluid warm-up.
1. Run engine for approximately five minutes set at the
middle of the speed range, without a load.
2. Move safety lever to "UNLOCK" position.
3. Slowly cycle boom, arm and bucket cylinders about five
times without a load to circulate the oil through the system.
Do this for five minutes.
4. Check for clearance and fully raise the front attachment.
Swing
clockwise 3 revolutions. Swing counterclockwise 3
revolutions.
5. Travel forward and reverse at low speed for two
revo
lutions of the drive sprocket.
WARNING
AVOID DEATH OR SERIOUS INJURY
If a problem or abnormal operation occurs, immediately
stop en
gine. Allow excavator to reach normal operating
temperature before starting work, especially in cold
weather.
HAOB410L
Figure 13
Lock
Unlock
EX1300566
Figure 14
FG014408
Figure 15