Operation and maintenance manual

Inspection, Maintenance and Adjustment
4-43
DX140R/DX140LCR
5. Clean the outer filter (4, Figure 67) by blowing compressed
air from the inside of the filter towards the outside. Do not
use more
than 205 kPa (30 psi) air pressure.
6. Check outer filter by shinning a light through it. If small
holes or thinner parts are found on the element after
cleaning it, replace the filter.
7. Clean the inside of the air cleaner body and the inside of
the air
cleaner cover. Do not use compressed air.
8. Properly install the air filter and cover.
9. After filter service be sure to install cover with arrow
s
pointing "UP".
NOTE: If after cleaning the outer filter, the air cleaner
clogged indicator remains "ON", replace the
outer and inner filters. Do not clean inner filter.
HAOC570L
Figure 68
FG000412
Figure 69