Operation and maintenance manual
DX140R/DX140LCRInspection, Maintenance and Adjustment
4-50
Change Oil in Travel Reduction Device
(One on Each Side of Unit)
NOTE: Drain oil after first 500 hours of operation or rebuild,
and every 1,000 hours thereafter.
1. Make sure that the machine is on firm and level ground.
2. Rotate the track until po
rts (1 thru 3, Figure 85) are in their
proper positions as shown.
3. Place a container under drain plug (2, Figure 85) and
remove plugs (1 thru 3) to drain the travel reduction gear
oil.
NOTE: Dispos
e of drained fluids in compliance with all
applicable environmental laws and regulations.
4. Install drain plug (2, Figure 85). Refill the travel reduction
gear case with fluid through fill port (3) until fluid level is at
port (1). Install level plug (1) and fill plug (3).
NO
TE: See "Fluid Ca
pacities" on page 4-9 for capacity.
5. Repeat this procedure on the other tr
avel reduction device.
Figure 85
FG028680FG028809
3
1
2
WARNING
AVOID DEATH OR SERIOUS INJURY
The gear oil is very hot after the machine has been
operat
ing. Shut all systems down and allow them to cool.
Before removing the motor case, loosen the plug slightly to
allow
pressurized air to escape. Residual pressure in the
travel reduction device can cause the plug to be dislodged
and oil to squirt out suddenly.
Reference
Number
Description
1 Oil Level Plug
2 Drain Plug
3 Fill Plug