Operation and maintenance manual

Inspection, Maintenance and Adjustment
4-77
DX140R/DX140LCR
1. Remove strainer cap (4, Figure 124) from strainer (3) on
end of inlet hose (5).
NOTE: Keep str
ainer cap (4, Figure 124) in a safe
location to reseal strainer (3) after refueling is
complete.
2. Insert inlet hose (5, Figure 124) into refueling tank.
3. Turn fuel pump switch (Figure 125) inside of battery box on
front side to "I" (ON) position.
NOTE: Tr
ansfer pump rate of flow is approximately
35 lpm (9.24 U.S. gpm). Use extra care not to
overfill fuel tank so fuel does not over flow.
4. Once fuel transfer is completed, immedia
tely turn switch to
"O" (OFF) position to stop pump.
5. Lift inlet hose (5, Figure 124) from fueling source and turn
switch to "I" (ON) position for two - three seconds to drain
remaining fuel from
hose to fuel tank.
6. Install strainer cap (4, Figure 124) on inlet strainer (3) and
return hose (5) to storage position.
FG014602
Figure 125